Abstract: Critical experiment studies were performed, varying the parameters U235, B10 and metal to water ratio, in the SM-2 7 x 7 core configuration with 38 stationary elements and seven control rods of the SM-1 (APPR-1) type. An experimental mock-up of the SM-1 was assembled using the basic SM-2 fuel plates. Excellent agreement between the SM-1 boron loading, determined by chemical analysis, and the SM-1 mock-up boron loading, for equivalent bank positions, was noted. Several SM-2 mock-ups, cold clean and midlife, were assembled and studied with regard to reflector effects, flow divider effects, relative control rod array worths, critical rod …
continued below
We've identified this
report
as a primary source within our collections. Researchers, educators, and students may find this report useful in their work.
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Abstract: Critical experiment studies were performed, varying the parameters U235, B10 and metal to water ratio, in the SM-2 7 x 7 core configuration with 38 stationary elements and seven control rods of the SM-1 (APPR-1) type. An experimental mock-up of the SM-1 was assembled using the basic SM-2 fuel plates. Excellent agreement between the SM-1 boron loading, determined by chemical analysis, and the SM-1 mock-up boron loading, for equivalent bank positions, was noted. Several SM-2 mock-ups, cold clean and midlife, were assembled and studied with regard to reflector effects, flow divider effects, relative control rod array worths, critical rod configurations, and relative power distributions. The results of these experiments indicate as satisfactory a U235 loading of 36.4 Kg and a B10 loading of 63.4 grams for the SM-2. Attention is drawn to numerous power peaks present in the active core. The open seven control rod array has a slight reactivity advantage over the closed seven array and consequent minor disadvantage with respect to "stuck rod" criteria.
Physical Description
xvi, 177 pages ; illustrations.
Notes
Digitized from microopaque cards.
Contract No. AT(30-3)-326 with the U.S. Atomic Energy Commission, New York Operations Office.
This report is part of the following collections of related materials.
Technical Report Archive and Image Library
The Technical Report Archive & Image Library (TRAIL) identifies, acquires, catalogs, digitizes and provides unrestricted access to U.S. government agency technical reports. The mission of TRAIL is to ensure preservation, discoverability, and persistent open access to government technical publications regardless of form or format.
Imaged from microcard, these technical reports describe research performed for U.S. government agencies from the 1930s to the 1960s. The reports were provided by the Technical Report Archive and Image Library (TRAIL).
Noaks, J. W.; McCool, W. J.; Robinson, R. A.; Schrader, E. W. & Weiss, S. H.SM-2 Critical Experiments : CE-1,
report,
November 30, 1959;
Schenectady, New York..
(https://digital.library.unt.edu/ark:/67531/metadc1201953/:
accessed June 12, 2026),
University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu;
crediting UNT Libraries Government Documents Department.