Abstract. The design, selection, and calculation of the Army Package Power Reactor shielding are described. The APPR-1, a prototype of a package reactor for remote locations, has a primary shield of iron and water. this shield has been adopted to permit fast erection and to provide low transported weight. economically, including transportation cost, the iron water shield is better than a lead water shield and is competitive with a concrete shield for a remote site. Because of the location at Fort Belvoir,Va., the shielding requirements for the APR-1 are considerably more stringent than those for a reactor at a remote …
continued below
We've identified this
report
as a primary source within our collections. Researchers, educators, and students may find this report useful in their work.
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Added Title:
U.S. Atomic Energy Commission Report APAE-3(Del)
Description
Abstract. The design, selection, and calculation of the Army Package Power Reactor shielding are described. The APPR-1, a prototype of a package reactor for remote locations, has a primary shield of iron and water. this shield has been adopted to permit fast erection and to provide low transported weight. economically, including transportation cost, the iron water shield is better than a lead water shield and is competitive with a concrete shield for a remote site. Because of the location at Fort Belvoir,Va., the shielding requirements for the APR-1 are considerably more stringent than those for a reactor at a remote base. Since the secondary shielding which surrounds the entire primary system must provide protection for personnel at any location outside the vapor container, concrete is provided for this need.
Physical Description
66 pages ; illustrations.
Notes
Digitized from microopaque cards.
Work performed under Contract No. AT(11-1)-318.
Includes bibliographical references (pages 64-66).
This report is part of the following collections of related materials.
Technical Report Archive and Image Library
The Technical Report Archive & Image Library (TRAIL) identifies, acquires, catalogs, digitizes and provides unrestricted access to U.S. government agency technical reports. The mission of TRAIL is to ensure preservation, discoverability, and persistent open access to government technical publications regardless of form or format.
Imaged from microcard, these technical reports describe research performed for U.S. government agencies from the 1930s to the 1960s. The reports were provided by the Technical Report Archive and Image Library (TRAIL).
Meem, J. L. (James Lawrence). & Fairbanks, F. B.Shielding Requirements for the Army Package Power Reactor,
report,
May 1, 1956;
Schenectady, New York..
(https://digital.library.unt.edu/ark:/67531/metadc1201934/:
accessed December 14, 2025),
University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu;
crediting UNT Libraries Government Documents Department.