A major part of the work in this quarter was on the combustor tests in task 2. Three of the six planned tests in this task were completed. The first two were parametric tests of nominal one shift, (8 hour) duration on coal. Due to failure of the UV detector in the first test only several hours of coal fired operation were completed. In the second test, coal fired operation continued for the planned one shift until the 4 ton coal bin was empty. After reviewing this work with DOE, it was decided to focus the remaining test on longer …
continued below
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this report.
Follow the links below to find similar items on the Digital Library.
Description
A major part of the work in this quarter was on the combustor tests in task 2. Three of the six planned tests in this task were completed. The first two were parametric tests of nominal one shift, (8 hour) duration on coal. Due to failure of the UV detector in the first test only several hours of coal fired operation were completed. In the second test, coal fired operation continued for the planned one shift until the 4 ton coal bin was empty. After reviewing this work with DOE, it was decided to focus the remaining test on longer duration operation with each test at one optimum condition. The third test was planned for two shift coal fired operation. Due to a problem with the pilot gas ignitor, combustion was delayed by 5 hours from 7 AM to Noon. As a result coal fired operation was limited to one shift between 3 PM and 11 PM. Throughout this period the combustor remained at one fixed condition with the use of computer control. Results for these three tests are presented in this report. Most of the work on the task 4 design and cost of a 20 MW combined gas-steam turbine power plant using the air cooled combustor was completed in the previous quarter. The results obtained by the A/E subcontractor on the installation desip and cost were evaluated in the present quarter and they are summarized in this report.
This report is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
Zauderer, B.Development and testing of industrial scale, coal fired combustion system, Phase 3,