An aquifer test at the Fenton Hill Geothermal Site was performed on a volcanic aquifer used for water supply. The test was made to determine the yield from the aquifer and to predict the amount of depletion that would occur with increased production during the period 1981 to 1985. A step-discharge test indicated the aquifer would comfortably yield 100 gal per min (gpm) without excessive water level drawdown in the pumping well. Drawdown test results indicated that the average aquifer transmissivity and storage coefficient are 5000 gal per day per foot (gpd/ft) and 0.07, respectively. Using these parameters, a drawdown …
continued below
Publisher Info:
Los Alamos National Lab., NM (USA)
Place of Publication:
New Mexico
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this report.
Follow the links below to find similar items on the Digital Library.
Description
An aquifer test at the Fenton Hill Geothermal Site was performed on a volcanic aquifer used for water supply. The test was made to determine the yield from the aquifer and to predict the amount of depletion that would occur with increased production during the period 1981 to 1985. A step-discharge test indicated the aquifer would comfortably yield 100 gal per min (gpm) without excessive water level drawdown in the pumping well. Drawdown test results indicated that the average aquifer transmissivity and storage coefficient are 5000 gal per day per foot (gpd/ft) and 0.07, respectively. Using these parameters, a drawdown was estimated to be at least 42 ft at the pumping well due to a withdrawal of 500 acre-ft of water over 5 yr. However, the presence of ground water boundaries indicates the aquifer is of limited extent, and because of this, the water level decline would probably be much greater. Past water level data indicate that there is little recharge to the aquifer.
This report is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
Becker, N. M.; Purtymun, W. D. & Ballance, W. C.Aquifer evaluation at Fenton Hill, October and November 1980,
report,
October 1, 1981;
New Mexico.
(https://digital.library.unt.edu/ark:/67531/metadc1109122/:
accessed December 2, 2024),
University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu;