Philadelphia's Gallery II shopping center complex: an analysis for the application of an integrated community energy system

PDF Version Also Available for Download.

Description

The results of ANL's study of the energy and economic aspects of energy system options for the Gallery II development are reported. Gallery II is a 1.3 million ft/sup 2/ office and shopping complex to be built in downtown Philadelphia. Seven centralized energy system alternatives, including five total energy systems and two heat-pump systems, were analyzed and compared with a decentralized, all-electric, conventional system. Comparisons among systems indicate that, in today's economy, the heat-pump-centered system which redistributes heat among different zones of buildings through the operation of heat pumps can achieve significant energy and economic savings.

Physical Description

Pages: 26

Creation Information

Lee, C.; Davis, A. & Kron, R. November 1, 1979.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

The results of ANL's study of the energy and economic aspects of energy system options for the Gallery II development are reported. Gallery II is a 1.3 million ft/sup 2/ office and shopping complex to be built in downtown Philadelphia. Seven centralized energy system alternatives, including five total energy systems and two heat-pump systems, were analyzed and compared with a decentralized, all-electric, conventional system. Comparisons among systems indicate that, in today's economy, the heat-pump-centered system which redistributes heat among different zones of buildings through the operation of heat pumps can achieve significant energy and economic savings.

Physical Description

Pages: 26

Notes

Dep. NTIS, PC A03/MF A01.

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: ANL/CNSV-TM-19(Vol.1)
  • Grant Number: W-31-109-ENG-38
  • DOI: 10.2172/5927573 | External Link
  • Office of Scientific & Technical Information Report Number: 5927573
  • Archival Resource Key: ark:/67531/metadc1100147

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • November 1, 1979

Added to The UNT Digital Library

  • Feb. 18, 2018, 3:59 p.m.

Description Last Updated

  • April 19, 2018, 2:37 p.m.

Usage Statistics

When was this report last used?

Congratulations! It looks like you are the first person to view this item online.

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Lee, C.; Davis, A. & Kron, R. Philadelphia's Gallery II shopping center complex: an analysis for the application of an integrated community energy system, report, November 1, 1979; Illinois. (digital.library.unt.edu/ark:/67531/metadc1100147/: accessed October 22, 2018), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.