The Lassen geothermal system consists of a central vapor-dominated reservoir underlain by hot water that discharges peripherally at lower elevations. The major thermal upflow at Bumpass Hell (elevation 2500 m) displays numerour superheated fumaroles, one of which in 1976 was 159/sup 0/C. Gas geothermometers from the fumarole areas and water geothermometers from boiling Cl-bearing waters at Morgan Hot Springs (elevation 1530 m; 8 km south of Bumpass Hell) and from 176/sup 0/C waters in a well 12 km southeast of Bumpass Hell both indicate 230 to 240/sup 0/C for the deep thermal water. With increasing distance from Bumpass Hell, gases ... continued below

Physical Description

Pages: 9

Creation Information

Muffler, L.J.P.; Nehring, N.L.; Truesdell, A.H.; Janik, C.J.; Clynne, M.A. & Thompson, J.M. January 1, 1982.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

The Lassen geothermal system consists of a central vapor-dominated reservoir underlain by hot water that discharges peripherally at lower elevations. The major thermal upflow at Bumpass Hell (elevation 2500 m) displays numerour superheated fumaroles, one of which in 1976 was 159/sup 0/C. Gas geothermometers from the fumarole areas and water geothermometers from boiling Cl-bearing waters at Morgan Hot Springs (elevation 1530 m; 8 km south of Bumpass Hell) and from 176/sup 0/C waters in a well 12 km southeast of Bumpass Hell both indicate 230 to 240/sup 0/C for the deep thermal water. With increasing distance from Bumpass Hell, gases are progressively depleted in H/sub 2/S relative to CO/sub 2/ and N/sub 2/, owing to oxidation of H/sub 2/S to pyrite, sulfur, and sulfates and to dilution with atmospheric N/sub 2/. H/sub 2/O/gas ratios and degree of superheat of fumaroles can be explained by mixing of steam of maximum enthalpy (2804 J g/sup -1/) with near-surface water and with the condensate layer overlying the vapor-dominated reservoir.

Physical Description

Pages: 9

Notes

USGS-Open File Service, Box 25425, Denver Fed. Center, Denver, CO 80225; 1.

Source

  • Other Information: Portions are illegible in microfiche products

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Other: DE84900439
  • Report No.: USGS-OFR-82-926
  • Grant Number: None
  • DOI: 10.2172/5456485 | External Link
  • Office of Scientific & Technical Information Report Number: 5456485
  • Archival Resource Key: ark:/67531/metadc1074889

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • January 1, 1982

Added to The UNT Digital Library

  • Feb. 4, 2018, 10:51 a.m.

Description Last Updated

  • March 27, 2018, 6:47 p.m.

Usage Statistics

When was this report last used?

Congratulations! It looks like you are the first person to view this item online.

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Muffler, L.J.P.; Nehring, N.L.; Truesdell, A.H.; Janik, C.J.; Clynne, M.A. & Thompson, J.M. Lassen geothermal system, report, January 1, 1982; United States. (digital.library.unt.edu/ark:/67531/metadc1074889/: accessed October 19, 2018), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.