As part of the Milliwatt Generator (MWG) Program, 12 simulant-fueled heat sources were fabricated double impact tested, and evaluated at Mound. Ten assemblies were tested at approx. 80 m/sec, and two were tested at approx. 105 m/sec. None of the strength members were breached; therefore, no fuel would have been released as a result of double impacts at the velocities and orientations tested at 450/sup 0/C. There was little difference in results for duplicate tests conducted approx. 80 and approx. 105 m/sec. Ten units contained liners that were embrittled prior to testing. This resulted in cracks in some of the …
continued below
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this report.
Follow the links below to find similar items on the Digital Library.
Description
As part of the Milliwatt Generator (MWG) Program, 12 simulant-fueled heat sources were fabricated double impact tested, and evaluated at Mound. Ten assemblies were tested at approx. 80 m/sec, and two were tested at approx. 105 m/sec. None of the strength members were breached; therefore, no fuel would have been released as a result of double impacts at the velocities and orientations tested at 450/sup 0/C. There was little difference in results for duplicate tests conducted approx. 80 and approx. 105 m/sec. Ten units contained liners that were embrittled prior to testing. This resulted in cracks in some of the liner that would not have occurred in normally fueled heat sources.
This report is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
Teaney, P. E.; Cartmill, W. B. & Wise, R. L.Testing and evaluation of doubly impacted simulant-fueled Milliwatt Generator heat sources,
report,
April 9, 1982;
Miamisburg, Ohio.