Kilowatt Isotope Power System: component test procedure for the ground demonstration system multi-power level combined rotating unit. 77-KIPS-61

PDF Version Also Available for Download.

Description

This test procedure (No. 402) provides a detailed description of the verification methods which shall be used in the developmental program to be conducted on the Combined Rotating Unit-(CRU) of the Kilowatt Isotope Power System KIPS, to fulfill the requirements of the Ground Demonstration Test Plan. The test objectives were to: establish operating conditions, overspeed conditions and to measure basic performance; measure output power; record spin-down data and calculate bearing losses; calculate turbine efficiency at steady state using spin down data and previously determined pump and alternator performance data; test 500 W(e) and 2000 W(e) units by replacing necessary hardware … continued below

Creation Information

Creator: Unknown. December 1, 1977.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by the UNT Libraries Government Documents Department to the UNT Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Creator

  • We've been unable to identify the creator(s) of this report.

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

This test procedure (No. 402) provides a detailed description of the verification methods which shall be used in the developmental program to be conducted on the Combined Rotating Unit-(CRU) of the Kilowatt Isotope Power System KIPS, to fulfill the requirements of the Ground Demonstration Test Plan. The test objectives were to: establish operating conditions, overspeed conditions and to measure basic performance; measure output power; record spin-down data and calculate bearing losses; calculate turbine efficiency at steady state using spin down data and previously determined pump and alternator performance data; test 500 W(e) and 2000 W(e) units by replacing necessary hardware in one of the units and measuring basic performance; and test one of the units in the horizontal axis to demonstrate zero g operation.

Notes

NTIS, PC A03/MF A01.

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: DOE/ET/33001-T15
  • Grant Number: AC02-77ET33001
  • Office of Scientific & Technical Information Report Number: 5038934
  • Archival Resource Key: ark:/67531/metadc1058968

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • December 1, 1977

Added to The UNT Digital Library

  • Jan. 22, 2018, 7:23 a.m.

Description Last Updated

  • Jan. 24, 2018, 1:23 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 9

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Kilowatt Isotope Power System: component test procedure for the ground demonstration system multi-power level combined rotating unit. 77-KIPS-61, report, December 1, 1977; United States. (https://digital.library.unt.edu/ark:/67531/metadc1058968/: accessed March 27, 2025), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.

Back to Top of Screen