We investigated the analysis method used by the International Atomic Energy Agency (IAEA) to determine the plutonium isotopic composition of highly enriched mixed oxides (MOX). The IAEA currently uses the Cicero multichannel analyzer and the IAEAPU algorithm for its analysis. In our investigation the plutonium isotopic measurements were found to be good for PuO/sub 2/ powder or low-enriched MOX, but acceptable for highly enriched MOX in IAEA special nuclear material (SNM) accountability applications. The gamma-ray interferences from /sup 235/U resulted in underestimation of the isotopic composition of /sup 239/Pu and overestimation of all other plutonium isotopes. Samples with high /sup …
continued below
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this report.
Follow the links below to find similar items on the Digital Library.
Description
We investigated the analysis method used by the International Atomic Energy Agency (IAEA) to determine the plutonium isotopic composition of highly enriched mixed oxides (MOX). The IAEA currently uses the Cicero multichannel analyzer and the IAEAPU algorithm for its analysis. In our investigation the plutonium isotopic measurements were found to be good for PuO/sub 2/ powder or low-enriched MOX, but acceptable for highly enriched MOX in IAEA special nuclear material (SNM) accountability applications. The gamma-ray interferences from /sup 235/U resulted in underestimation of the isotopic composition of /sup 239/Pu and overestimation of all other plutonium isotopes. Samples with high /sup 240/Pu content were found to have significantly higher error in plutonium isotopic analyses of highly enriched MOX. Code modifications or use of calibration curves are necessary for plutonium isotopic analyses of highly enriched MOX in IAEA SNM accountability applications.
This report is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
Clement, S. D. & Augustson, R. H.Plutonium isotopic analysis of highly enriched mixed oxides,