The temperature, geometry, and flow conditions which exist in the EGCR were duplicated in a mock-up designated as the EGCR Burning Rig to establish the combustion conditions in the reactor. The conditions under which the EGCR Burning Rig will ignite were established and an analytical model was developed which predicts these conditions. Because the Burning Rig cannot exactly dupIicate the reactor situation the final prediction of the safety of the EGCR must rest on computer calculations employing the above analytical model. No advantage in retarding combustion was found in using silicon carbide coated fuel sleeves. The negative results of these …
continued below
Publisher Info:
General Electric Co. Hanford Atomic Products Operation, Richland, Wash.
Place of Publication:
Richland, Washington
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this report.
Follow the links below to find similar items on the Digital Library.
Description
The temperature, geometry, and flow conditions which exist in the EGCR were duplicated in a mock-up designated as the EGCR Burning Rig to establish the combustion conditions in the reactor. The conditions under which the EGCR Burning Rig will ignite were established and an analytical model was developed which predicts these conditions. Because the Burning Rig cannot exactly dupIicate the reactor situation the final prediction of the safety of the EGCR must rest on computer calculations employing the above analytical model. No advantage in retarding combustion was found in using silicon carbide coated fuel sleeves. The negative results of these tests are due both to the particular geometry of the EGCR moderator and sleeves as well as to the fact that all sleeves tested contained imperfections in the coatings. Chlorine was demonstrated to be an effective agent for extinguishing graphite fires. Concentrations in air of about 1% were observed to extinguish graphite fires at temperatures as high as 1000 deg C. (auth)
This report is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
de Halas, D. R.; Dahl, R. E. & Jackson, J. L.Hanford Studies for EGCR Combustion Characteristics. Summary Report,
report,
October 10, 1961;
Richland, Washington.
(https://digital.library.unt.edu/ark:/67531/metadc1056230/:
accessed December 4, 2024),
University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu;
crediting UNT Libraries Government Documents Department.