Stirling total energy systems study. Final report, May 15, 1976--June 13, 1977

PDF Version Also Available for Download.

Description

The application of Stirling cycle prime movers to total energy power generation systems was investigated. Electrical, heating, and cooling demand profiles for a typical residential complex, hospital, and office building were studied, and alternative Stirling total energy systems were conceptualized for each site. These were analyzed in detail and contrasted with purchased-power systems for these sites to determine fuel-energy savings and investment attractiveness. The residential complex and hospital would be excellent candidates for total energy systems, and prime movers in the 1000 kW output range would be required. Stirling engines with so large an output have not been built to … continued below

Physical Description

Pages: 190

Creation Information

Lehrfeld, D. August 1, 1977.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by the UNT Libraries Government Documents Department to the UNT Digital Library, a digital repository hosted by the UNT Libraries. It has been viewed 54 times. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Author

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

The application of Stirling cycle prime movers to total energy power generation systems was investigated. Electrical, heating, and cooling demand profiles for a typical residential complex, hospital, and office building were studied, and alternative Stirling total energy systems were conceptualized for each site. These were analyzed in detail and contrasted with purchased-power systems for these sites to determine fuel-energy savings and investment attractiveness. The residential complex and hospital would be excellent candidates for total energy systems, and prime movers in the 1000 kW output range would be required. Stirling engines with so large an output have not been built to date, although there would be no fundamental technical barrier to prevent this. However, careful consideration must be given to the following technological decision areas before arriving at a final design, if its potential is to be realized: engine configuration, hotside heat exchange interface, engine control system, internal gas seals, and advanced coal combustion technology. The principal advantage of a Stirling prime mover in this application, in view of national concern over present and future dependence on oil, is that it could utilize low-grade liquid fuels and coal.

Physical Description

Pages: 190

Notes

Dep. NTIS, MF A01.

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • August 1, 1977

Added to The UNT Digital Library

  • Jan. 22, 2018, 7:23 a.m.

Description Last Updated

  • May 17, 2019, 1:47 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 54

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Lehrfeld, D. Stirling total energy systems study. Final report, May 15, 1976--June 13, 1977, report, August 1, 1977; United States. (https://digital.library.unt.edu/ark:/67531/metadc1055288/: accessed November 9, 2026), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.

Back to Top of Screen