CORROSION ANALYSIS: LOW-CAPACITY PUMP. Large Sodium Pump Study, Phase II. Page: 15 of 30

Table 2

Estimated Total Corrosion after 20 Years at 900 F plus 1000 Hours at 1200*F

UKAEA Data (Velocity Independent)
02 Level (ppm) 10 15 30
Thickness 1.3 2.3 10.5
Loss (mils)
G.E. Data (Velocity Dependent) at 15 ppm 02
Velocity Exponent 0.2 0.884 0.16
Thickness Loss (mils) Mean Max. Min. Mean Max. Min.
Na Velocity (fps)
20 0.047 0.82 0.0027 0.22 5.6 0.008
40 0.62 1.1 0.0037 0.76 24.5 0.024
80 0.71 1.25 0.0041 1.4 54 0.041
100 0.79 1.35 .0043 1.8 62 .048

Upcoming Pages

Here’s what’s next.

upcoming item: 16 16 of 30
upcoming item: 17 17 of 30
upcoming item: 18 18 of 30
upcoming item: 19 19 of 30

Show all pages in this report.

This report can be searched. Note: Results may vary based on the legibility of text within the document.

Tools / Downloads

Get a copy of this page .

Citing and Sharing

Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.

Reference the current page of this Report.

Thomas, K.C. & Shiels, S. CORROSION ANALYSIS: LOW-CAPACITY PUMP. Large Sodium Pump Study, Phase II., report, October 31, 1970; Madison, Pennsylvania. (https://digital.library.unt.edu/ark:/67531/metadc1034653/m1/15/ocr/: accessed April 24, 2019), University of North Texas Libraries, Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.