It is shown that the method of x-ray emission spectrometry can be extended advantageously to the determination of plutonium in solution, Since K and L x-ray emission from the elements of higher atomic number is not measurably influenced by valence state of the emitting atom or ion, this physical method is especially attractive for elements such as plutonium whose chemistry is intricate and whose chemical analysis is complicated by several valence states existing in solution. Nor is it affected by variations in isotopic content as is the widely used radiochemical assay for plutonium. With a total amount of plutonium between …
continued below
Publisher Info:
Argonne National Lab., Lemont, Ill.
Place of Publication:
Lemont, Illinois
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this report.
Follow the links below to find similar items on the Digital Library.
Description
It is shown that the method of x-ray emission spectrometry can be extended advantageously to the determination of plutonium in solution, Since K and L x-ray emission from the elements of higher atomic number is not measurably influenced by valence state of the emitting atom or ion, this physical method is especially attractive for elements such as plutonium whose chemistry is intricate and whose chemical analysis is complicated by several valence states existing in solution. Nor is it affected by variations in isotopic content as is the widely used radiochemical assay for plutonium. With a total amount of plutonium between 0.4 and 0.8 mg the standard deviation of a single result is less than 1 per cent. For samples of diverse origin interferences are eliminated, usually by simple chemical pre-treatment or by separation procedures, to give a clean solution for analysis. On the other hand, for large numbers of samples with a comparable matrix, it is worthwhile to devise calibration standards so that such samples can be analyzed directly. (auth)
This report is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
Flikkema, D. S. & Schablaske, R. V.An X-Ray Spectrometric Method for Determination of Plutonium in Solution,
report,
November 1, 1957;
Lemont, Illinois.
(https://digital.library.unt.edu/ark:/67531/metadc1019667/:
accessed June 6, 2026),
University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu;
crediting UNT Libraries Government Documents Department.