UNCLASSIFIED -17- HW-49542
The uranium extraction behavior of the two cartridges was also
similar. They both gave H. T. U. values between 0. 6 and 1. 0 foot at pulse
frequencies ranging from 60 to 100 cycles/minute and volume velocities of
500 to 1000 gal/hr - sq ft. It is also of interest to note that the nozzle plate
cartridge operated just as efficiently with the aqueous phase continuous.
Scrub Section. The most promising scrub section cartridge found was a
mixed cartridge containing alternate pairs of fluorothene and stainless steel
sieve plates. The fluorothene plates had 3/16-inch-diameter holes and 23
per cent free area. The stainless steel plates had 0. 08-inch-diameter holes
and 21 per cent free area. A one-inch plate spacing was used throughout.
The mixed cartridge had flooding pulse frequencies of 125 and 105
cycles/minute at volume velocities of 250 and 500* gal/hr - sq ft respec-
tively. For comparison, a "standard cartridge" scrub section (aqueous
phase continuous)showed flooding frequencies of 125 and 85 cycles/minute
at similar throughputs.
The extraction section controlled the flooding only at lower through-
puts for the aqueous phase continuous case. However, extraction section
controlled the flooding at all throughputs studied for the organic phase con-
tinuous case.
Scrub section efficiency studies were based on the transfer of
chloride ion which has an organic-to-aqueous distribution ratio between
0. 12 and 0. 13. This is about the same order-of -magnitude as might be
expected of some fission product distribution ratios.
Tests made in a scrub section containing a "standard cartridge"
indicated that the efficiency was sharply frequency sensitive. H. T. U.
values ranged from 3. 2 to 1. 8 feet at pulse frequencies of 60 and 100 cycles/
minute, respectively (volume velocities = 250 to 500 gal/hr - sq ft).
*A scrub section volume velocity of 500 gal/hr - sq ft is equivalent in uran-
ium capacity to an extraction section volume velocity of 1000 gal/hr - sq ft
for a dual-diameter column with a scrub-to-extraction-diameter ratio of
4 to 3.UNCLASSIFIED
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Geier, R. G. Application of the Pulse Column to the Purex Process, report, April 1, 1957; Richland, Washington. (https://digital.library.unt.edu/ark:/67531/metadc1017719/m1/19/: accessed April 18, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.