The characteristic square output currert pulse from a discharging coaxial cable has been utilized to explode wires of 1-mil diameter. The primary pulse duration was 3 mu sec and was variable in amplitude to a maximunn of 600 amperes. Voltage and current waveforms were recorded on a high-speed oscilloscope. Resolution of the system is better than 10/sup -8/ sec, thus enabling accurate determination of the resistance history of the malerial being studied. A survey of the behavior of various metals is presented, and the results of certain parameter studies, such as, geometry, external environment, and current density, are discussed. It …
continued below
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this report.
Follow the links below to find similar items on the Digital Library.
Description
The characteristic square output currert pulse from a discharging coaxial cable has been utilized to explode wires of 1-mil diameter. The primary pulse duration was 3 mu sec and was variable in amplitude to a maximunn of 600 amperes. Voltage and current waveforms were recorded on a high-speed oscilloscope. Resolution of the system is better than 10/sup -8/ sec, thus enabling accurate determination of the resistance history of the malerial being studied. A survey of the behavior of various metals is presented, and the results of certain parameter studies, such as, geometry, external environment, and current density, are discussed. It is shown that end effects contribute to the measured length of the sample, and that the energy to burst is dependent on current density. A new experimental system capable of producing square current pulses with an amplitude of 2000 amperes is described. (auth)
This report is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
Tucker, T.J. & Neilson, F.W.The Electrical Behavior of Fine Wires Exploded by a Coaxial Cable Discharge System,
report,
May 1, 1959;
Albuquerque, New Mexico.
(https://digital.library.unt.edu/ark:/67531/metadc1017635/: