ORNL/TM-2010/018
OAK RIDGE
NATIONAL LABORATORY
MANAGED BY UT-BATTELLE
FOR THE DEPARTMENT OF ENERGY
Two-Dimensional Thermal Hydraulic
Analysis and Benchmark in Support of
HFIR LEU Conversion using COMSOL
September 2010
J. D. Freels
I. T. Bodey
R. V. Arimilli
K. T. LoweUT-BATTELLE
ORNL-27 (4-00)
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Freels, James D; Bodey, Isaac T; Lowe, Kirk T & Arimilli, Rao V. 2D Thermal Hydraulic Analysis and Benchmark in Support of HFIR LEU Conversion using COMSOL, report, September 1, 2010; United States. (https://digital.library.unt.edu/ark:/67531/metadc1015974/m1/1/: accessed April 24, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.