A careful measurement of the system noise performance for all 12 Debuncher stochastic cooling systems has been performed. The opportunity to make the measurement was due to a pickup tank warm up to fix a bad preamplifier. A HP power meter and spectrum analyzer were used to measure the noise power and spectral characteristics of each system. Signals were monitored in the tunnel at the medium level transfer switch, before any variable gain devices. Noise power levels observed ranged between -10 to -30 dBm, which is well within the linear calibration range of the power meter. The noise floor of ... continued below

Physical Description

2 pages

Creation Information

Pasquinelli, Ralph J. March 22, 2001.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Author

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

A careful measurement of the system noise performance for all 12 Debuncher stochastic cooling systems has been performed. The opportunity to make the measurement was due to a pickup tank warm up to fix a bad preamplifier. A HP power meter and spectrum analyzer were used to measure the noise power and spectral characteristics of each system. Signals were monitored in the tunnel at the medium level transfer switch, before any variable gain devices. Noise power levels observed ranged between -10 to -30 dBm, which is well within the linear calibration range of the power meter. The noise floor of the power meter was measured to be below -40 dBm. The temperature of the tunnel for the warm measurements was 80 degrees F or 300 Kelvin. The tanks had been at tunnel temperature for weeks when the warm measurement was made. There was no vacuum in the tanks for the warm measurement. The cold temperature of the tanks at liquid helium was 4.5-5 K. 5K was used in the calculations. No component changes were made between the measurements. The gain of the cryogenic amplifier increases with a decrease in operating temperature. The gain of the cryo amplifier was carefully measured both warm and cold so that this change could be taken into account. The Noise Figure in dB and effective noise temperature are derived from the equations below. T2-T1 is the difference in operation temperature in degrees Kelvin, in this case 300-5 or 295 deg. K. Y is the excess noise ratio, which is measured in dB by the power meter by taking the difference in noise power between warm and cold measurements. This log value must be converted to linear for use in this equation. The value for Y is also corrected for the increase in gain due to the change in the operating temperature of the amplifier. This data was derived from the warm and cold preamp temperatures measured in the tunnel. The noise figure NF used in the effective noise temperature equation must also be converted to linear. Except for two systems where noise was measured to be below reasonable levels (in red on spreadsheet), the numbers appear to be reasonable.

Physical Description

2 pages

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: FERMILAB-PBAR-NOTE-661
  • Grant Number: AC02-07CH11359
  • DOI: 10.2172/984573 | External Link
  • Office of Scientific & Technical Information Report Number: 984573
  • Archival Resource Key: ark:/67531/metadc1013280

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • March 22, 2001

Added to The UNT Digital Library

  • Oct. 14, 2017, 8:36 a.m.

Description Last Updated

  • Nov. 3, 2017, 9:25 p.m.

Usage Statistics

When was this report last used?

Congratulations! It looks like you are the first person to view this item online.

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Pasquinelli, Ralph J. Noise Performance of the Debuncher Stchastic Cooling Systems, report, March 22, 2001; Batavia, Illinois. (digital.library.unt.edu/ark:/67531/metadc1013280/: accessed June 25, 2018), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.