It is requested that a design be initiated for the primary piping static test. This test is necessary to provide information as to the reliability of the pipe subjected to reactor operating conditions. The test conditions are as follows: temperature - 2000 F (isothermal), pressure effective - 42 psi, and test time - 10,000 hours. It will be necessary to test two sizes of pipe as shown on the preliminary piping layout (2.250-inch O.D. x .095-inch wall and 3 1/2 SCH. 10 pipe). The test specimens shall be jacketed in an inconel containment vessel. The test rig should be similar ... continued below

Creation Information

O'Brien, R.W. November 30, 1961.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Author

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

It is requested that a design be initiated for the primary piping static test. This test is necessary to provide information as to the reliability of the pipe subjected to reactor operating conditions. The test conditions are as follows: temperature - 2000 F (isothermal), pressure effective - 42 psi, and test time - 10,000 hours. It will be necessary to test two sizes of pipe as shown on the preliminary piping layout (2.250-inch O.D. x .095-inch wall and 3 1/2 SCH. 10 pipe). The test specimens shall be jacketed in an inconel containment vessel. The test rig should be similar to the design of the 4-inch pressure vessels (T-1030244). In addition an outer containment vessel constructed of stainless steel must be provided around the clam shell heaters and the inconel containment vessel. This is to provide an inert atmosphere for the inconel vessel. Provisions should be made in the design for a 1/4-inch clad thermocouple. It is planned to use the pipe test as a vehicle for studying experimental Tc's (Cb-Mo and W-W.26% Re).

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: CNLM-3912
  • Grant Number: AT(30-1)-2789
  • DOI: 10.2172/991703 | External Link
  • Office of Scientific & Technical Information Report Number: 991703
  • Archival Resource Key: ark:/67531/metadc1012908

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • November 30, 1961

Added to The UNT Digital Library

  • Oct. 14, 2017, 8:36 a.m.

Description Last Updated

  • Oct. 24, 2017, 7:36 p.m.

Usage Statistics

When was this report last used?

Congratulations! It looks like you are the first person to view this item online.

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

O'Brien, R.W. Primary Piping Static Test Design Request, report, November 30, 1961; United States. (digital.library.unt.edu/ark:/67531/metadc1012908/: accessed December 11, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.