Search Results

Advanced search parameters have been applied.
open access

DWPF waste glass Product Composition Control System

Description: The Defense Waste Processing Facility (DWPF) will be used to blend aqueous radwaste (PHA) with solid radwaste (Sludge) in a waste receipt vessel (the SRAT). The resulting SRAT material is transferred to the SME an there blended with ground glass (Frit) to produce a batch of melter feed slurry. The SME material is passed to a hold tank (the MFT) which is used to continuously feed the DWPF melter. The melter. The melter produces a molten glass wasteform which is poured into stainless steel canist… more
Date: January 1, 1992
Creator: Brown, K.G. & Postles, R.L.
Partner: UNT Libraries Government Documents Department
open access

Safety rod latch inspection

Description: During an attempt to raise control rods from the 100 K reactor in December, one rod could not be withdrawn. Subsequent investigation revealed that a small button'' in the latch mechanism had broken off of the lock plunger'' and was wedged in a position that prevented rod withdrawal. Concern that this failure may have resulted from corrosion or some other metallurgical problem resulted in a request that SRL examine six typical latch mechanisms from the 100 L reactor by use of radiography and met… more
Date: February 1, 1992
Creator: Leader, D.R.
Partner: UNT Libraries Government Documents Department
open access

Configuration Management Program Plan

Description: Westinghouse Savannah River Company (WSRC) has established a configuration management (CM) plan to execute the SRS CM Policy and the requirements of the DOE Order 4700.1. The Reactor Restart Division (RRD) has developed its CM Plan under the SRS CM Program and is implementing it via the RRD CM Program Plan and the Integrated Action Plan. The purpose of the RRD CM program is to improve those processes which are essential to the safe and efficient operation of SRS production reactors. This docume… more
Date: September 25, 1991
Partner: UNT Libraries Government Documents Department
open access

Development of a mathematical model of a packed column for benzene removal from salt solutions

Description: A mathematical model of a packed column was developed to describe the removal of benzene from radioactive salt solutions at the Savannah River Site. The model was developed from existing, generalized mass transfer correlations for randomly dumped packing, and the correlations were adapted for structured packing. Thermophysical data specific to the solutions of interest were incorporated into the model. Verification of the code was completed using operating data from stripping columns at other l… more
Date: January 1, 1989
Creator: Georgeton, G.K.
Partner: UNT Libraries Government Documents Department
open access

Westinghouse independent safety review of Savannah River production reactors

Description: Westinghouse Electric Corporation has performed a safety assessment of the Savannah River production reactors (K,L, and P) as requested by the US Department of Energy. This assessment was performed between November 1, 1988, and April 1, 1989, under the transition contract for the Westinghouse Savannah River Company's preparations to succeed E.I. du Pont de Nemours Company as the US Department of Energy contractor for the Savannah River Project. The reviewers were drawn from several Westinghouse… more
Date: April 1, 1989
Creator: Leggett, W. D.; McShane, W. J. (Westinghouse Hanford Co., Richland, WA (USA)); Liparulo, N. J.; McAdoo, J. D.; Strawbridge, L. E. (Westinghouse Electric Corp., Pittsburgh, PA (USA). Nuclear and Advanced Technology Div.); Toto, G. (Westinghouse Electric Corp., Pittsburgh, PA (USA). Nuclear Services Div.) et al.
Partner: UNT Libraries Government Documents Department
open access

FLOWTRAN benchmarking with onset of flow instability data from 1988 Columbia University single-tube OFI experiment

Description: Benchmarking FLOWTRAN, Version 16.2, with an Onset of Significant Voiding (OSV) criterion against measured Onset of Flow Instability (OFI) data from the 1988--89 Columbia University downflow tests has shown that FLOWTRAN with OSV is a conservative OFI predictor. Calculated limiting flow rates based on the Savannah River Site (SRS) OSV criterion were always higher than the measured flow rates at OFI. This work supplements recent FLOWTRAN benchmarking against 1963 downflow tests at Columbia Unive… more
Date: June 1, 1990
Creator: Chen, K.; Paul, P. K. & Barbour, K. L.
Partner: UNT Libraries Government Documents Department
open access

Predicting aquatic macrophyte modeling of a new freshwater lake using remote sensing

Description: Par Pond and L Lake are reservoirs on the Savannah River Site in South Carolina. Beds of aquatic macrophytes (primarily cattail and waterlilies) exist in Par Pond and are now beginning to develop in L Lake. Biophysical knowledge about Par Pond was used to develop environmental constraint criteria' to predict the future spatial distribution of aquatic macrophytes in L Lake. The L Lake biophysical data were placed in a 5 {times} 5 m raster geographic information system (GIS) and analyzed using Bo… more
Date: January 1, 1992
Creator: Jensen, J. R.; Narumalani, S.; Weatherbee, O.; Morris, K. S., Jr. & Mackey, H. E., Jr.
Partner: UNT Libraries Government Documents Department
open access

H-Area Seepage Basins

Description: During the third quarter of 1990 the wells which make up the H-Area Seepage Basins (H-HWMF) monitoring network were sampled. Laboratory analyses were performed to measure levels of hazardous constituents, indicator parameters, tritium, nonvolatile beta, and gross alpha. A Gas Chromatograph Mass Spectrometer (GCMS) scan was performed on all wells sampled to determine any hazardous organic constituents present in the groundwater. The primary contaminants observed at wells monitoring the H-Area Se… more
Date: December 1, 1990
Creator: Stejskal, G.
Partner: UNT Libraries Government Documents Department
open access

Comparison of TRAC and RELAP5 reactor system calculations for a DEGB LOCA in K-14. 1

Description: A comparison of TRAC and RELAP5 predictions of steady-state and DEGB LOCA results (FI phase) for K-14.1 has been made. Both codes had been previously benchmarked against 1985 L Reactor AC Flow data and were under configuration control. The purpose of the code-to-code comparison is to provide insight on the transient uncertainty in TRAC plenum and tank bottom plenum pressures. The comparisons focus on LOCA results between 0.5 and 2.0 s, which is the primary period of interest for Flow Instabilit… more
Date: September 1, 1990
Creator: Griggs, D.P. (Westinghouse Savannah River Co., Aiken, SC (United States)) & Liebmann, M.L. (Wais and Associates (United States))
Partner: UNT Libraries Government Documents Department
open access

F/H Area ETF effluent (H-016 outfall), ceriodaphnia survival/reproduction test, test date: March 21, 1991

Description: This toxicity test was conducted to determine if the effluent from the F/H area at Savannah River Plant affects the survival or reproduction of the test organisms during a seven day period. The test involved exposing the test organisms to a series of dilutions of the effluent. At each dilution the survival and reproduction of ten test organisms was recorded. Each effluent dilution was compared to a control set of test organisms. Survival data were analyzed by Fisher's Exact Test and the Trimmed… more
Date: August 1, 1991
Creator: Specht, Winona L.
Partner: UNT Libraries Government Documents Department
open access

Examples of robots and teleoperators at the Savannah River Site

Description: The Savannah River Site manufactures nuclear materials for the US Department of Energy. In recent years robots and mobile teleoperators have been used to reduce the radiation exposure of personnel at this site. Two examples of robots that have significantly reduced radiation exposure are the Shielded Cells Waste Handling Robot and the Shielded Cells Sample Handling Robot. The Shielded Cells Waste Handling Robot has been in operation for over four years. It removes cans of radioactive waste from… more
Date: January 1, 1989
Creator: Ward, C. R.; Heckendorn, F. M. & Vandewalle, R. C.
Partner: UNT Libraries Government Documents Department
open access

The product consistency test for the DWPF wasteform

Description: The preliminary specifications on the glass wasteform to be produced by the Defense Waste Processing Facility (DWPF) require extensive characterization of the glass product both before actual production begins and then during production. To aid in this characterization, a leach test was needed that was easily reproducible, could be performed remotely on highly radioactive samples, and could yield results rapidly. Several standard leach tests were examined with a variety of test configurations. … more
Date: January 1, 1990
Creator: Jantzen, Carol M. & Bibler, N. E.
Partner: UNT Libraries Government Documents Department
open access

Internal dosimetry technical basis manual

Description: The internal dosimetry program at the Savannah River Site (SRS) consists of radiation protection programs and activities used to detect and evaluate intakes of radioactive material by radiation workers. Examples of such programs are: air monitoring; surface contamination monitoring; personal contamination surveys; radiobioassay; and dose assessment. The objectives of the internal dosimetry program are to demonstrate that the workplace is under control and that workers are not being exposed to r… more
Date: December 20, 1990
Partner: UNT Libraries Government Documents Department
open access

Defense waste processing facility startup progress report

Description: The Savannah River Site (SRS) has been operating a nuclear fuel cycle since the 1950's to produce nuclear materials in support of the national defense effort. About 83 million gallons of high level waste produced since operation began have been consolidated into 33 million gallons by evaporation at the waste tank farm. The Department of Energy has authorized the construction of the Defense Waste Processing Facility (DWPF) to immobilize the waste as a durable borosilicate glass contained in stai… more
Date: January 1, 1992
Creator: Iverson, D.C. & Elder, H.H.
Partner: UNT Libraries Government Documents Department
open access

Design of a full scale model fuel assembly for full power production reactor flow excursion experiments

Description: A novel full scale production reactor fuel assembly model was designed and built to study thermal-hydraulic effects of postulated Savannah River Site (SRS) nuclear reactor accidents. The electrically heated model was constructed to simulate the unique annular concentric tube geometry of fuel assemblies in SRS nuclear production reactors. Several major design challenges were overcome in order to produce the prototypic geometry and thermal-hydraulic conditions. The two concentric heater tubes (to… more
Date: January 1, 1990
Creator: Nash, C. A. (Westinghouse Savannah River Co., Aiken, SC (United States)); Blake, J. E. & Rush, G. C. (Babcock and Wilcox Co., Alliance, OH (United States))
Partner: UNT Libraries Government Documents Department
open access

Savannah River Site computing architecture migration guide

Description: The SRS Computing Architecture is a vision statement for site computing which enumerates the strategies which will guide SRS computing efforts for the 1990s. Each strategy is supported by a number of feature statements which clarify the strategy by providing additional detail. Since it is a strategic planning document, the Architecture has sitewide applicability and endorsement but does not attempt to specify implementation details. It does, however, specify that a document will be developed to… more
Date: July 30, 1991
Partner: UNT Libraries Government Documents Department
open access

Evaluation of filter media for clarification of partially dissolved residues containing plutonium

Description: A common process in the chemical industry employs the leaching of a desirable component from an insoluble substrate, followed by filtration to produce a clarified solution of the desirable component and a discardable residue. The work described here involved evaluating sintered metal filter media for separating dissolved plutonium from undissolved residues generated at various locations owned by the Department of Energy throughout the United States. The work was performed during a six-week assi… more
Date: October 9, 1989
Creator: Foley, E.S.
Partner: UNT Libraries Government Documents Department
open access

Flow instability in a vertical annulus under steady state and transient conditions

Description: Experimental data have been obtained for the occurrence of flow instability in a vertical annulus under steady state and transient down-flow conditions. The results show that the primary factor affecting the onset of flow instability is the Q{sub ratio} parameter (a measure of the void production in a channel). In addition, it is shown that for steady state conditions good agreement exists between the single annulus data and single tube data based upon the same L/D ratio. The results also indic… more
Date: January 1, 1992
Creator: Fighetti, C.; Kokolis, S.; Maciuca, C.; Reddy, D.G.; Yang, B.; Carrano, V. (Columbia Univ., New York, NY (United States)) et al.
Partner: UNT Libraries Government Documents Department
open access

Seismic fragility analysis of buried steel piping at P, L, and K reactors

Description: Analysis of seismic strength of buried cooling water piping in reactor areas is necessary to evaluate the risk of reactor operation because seismic events could damage these buried pipes and cause loss of coolant accidents. This report documents analysis of the ability of this piping to withstand the combined effects of the propagation of seismic waves, the possibility that the piping may not behave in a completely ductile fashion, and the distortions caused by relative displacements of structu… more
Date: October 1, 1989
Creator: Wingo, H.E.
Partner: UNT Libraries Government Documents Department
open access

(Intrusion Path Analysis)

Description: The design and implementation of an Intrusion Path Analysis (IPA) function came about as a result of the upgrades to the security systems at the Savannah River Site (SRS), near Aiken, South Carolina. The stated requirements for IPA were broad, leaving opportunity for creative freedom during design and development. The essential elements were that it: be based on alarm and sensor state data; consider insider as well as outsider threats; be flexible and easily enabled or disabled; not be processo… more
Date: January 1, 1989
Creator: Hardwick, R D
Partner: UNT Libraries Government Documents Department
open access

Seismic analysis of reactor exhaust air filter compartment

Description: The Filter Compartment (FC) in this analysis is a generic reactor airborne activity confinement filter compartment which possesses all the essential physical and mechanical properties of the Savannah River Site (SRS) confinement filters of Reactor Buildings K, L, and P. The filters belong to the Airborne Activity Confinement System (AACS). These filters absorb a significant amount of radioactive effluents from the exhausting air. The seismic excitation is input indirectly from the output of the… more
Date: September 24, 1990
Creator: Gong, Chung; Funderburk, E.L. & Jerrell, J.W.
Partner: UNT Libraries Government Documents Department
open access

A method to estimate the concentration of elements in smoke from burning vegetation growing in contaminated soil

Description: The Savannah River Site has areas where soil is contaminated with metals and/or radionuclides. Many of these areas are surrounded by native vegetation which is growing adjacent to the area and where the roots have penetrated into the contaminated soil of the area. In some cases vegetation has actually invaded the contaminated area. Even though the volume of contaminated vegetation is small, there are problems associated with its disposal. Vegetation decomposes quickly after burial and the volum… more
Date: March 4, 1991
Creator: Murphy, C. E. Jr.
Partner: UNT Libraries Government Documents Department
open access

Resource Conservation and Recovery Act (RCRA)

Description: This Resource Conservation and Recovery Act (RCRA) Facility Investigation Program Plan has been developed to provide a framework for the completion of RCRA Facility Investigations (RFI) at identified units on the Savannah Rive Site (SRS) facility. As such, the RFI Program Plan provides: technical guidance for all work to be performed, managerial control, a practical, scientific approach. The purpose of this Overview is to demonstrate how the basic RFI Program Plan elements (technical, managemen… more
Date: June 30, 1989
Partner: UNT Libraries Government Documents Department
open access

Considerations for imaging system implementation in a networked environment

Description: Information storage and retrieval systems that utilize raster images are increasing in popularity on a wide variety of platforms. Image systems typically involve the transmission of data files in the 100 KiloByte to 1 MegaByte range to users on specialized workstations who expect retrieval in a matter of seconds. The results of the pilot study outlines the potential for the sharing of image information among various platforms and systems, and sets expectations regarding the level of integration. more
Date: January 1, 1991
Creator: Hudson, B.J.
Partner: UNT Libraries Government Documents Department
Back to Top of Screen