Some Effects of Exposure to Exhaust-Gas Streams on Emittance and Thermoelectric Power of Bare-Wire Platinum Rhodium - Platinum Thermocouples
Description:
Thermocouples were exposed to exhaust gases from the combustion of propane, 72-octane gasoline, and JP-4 fuel. Exposure increased the emissivity of the thermocouple wire, which increased its radiation error. Two methods are presented for determining the emittance of the wires. The emissivity of a clean platinum rhodium-platinum thermocouple was approximately 0.2 in the temperature range investigated, while the emittance of an exposed thermocouple coated with exhaust residue was about 0.5. The e…
more
Date:
August 1954
Creator:
Glawe, George E. & Shepard, Charles E.
Item Type:
Refine your search to only
Report
Partner:
UNT Libraries Government Documents Department