You limited your search to:
Partner:
UNT Libraries Government Documents Department
Serial/Series Title:
NACA Memorandum Report
Collection:
National Advisory Committee for Aeronautics Collection
The problem of landing
Date: February 1, 1922
Creator: Pistolesi, E
Description: The author discusses various aspects of landing aircraft such as the actual process of touchdown and the problems associated with the tail skid touching the ground before the landing gear.
Contributing Partner: UNT Libraries Government Documents Department
Permallink:digital.library.unt.edu/ark:/67531/metadc53631/
Cooling of Gas Turbines, 2, Effectiveness of Rim Cooling of Blades
Date: September 20, 1945
Creator: Wolfenstein, Lincoln
Description: An analysis of rim cooling, which cools the blade by condition alone, was conducted. Gas temperatures ranged from 1300 degrees to 1900 degrees F and rim temperatures from 0 degrees to 1000 degrees F below gas temperatures. Results show that gas temperature increases up to 200 degrees F are permissible provided that the blades are cooled by 400 degrees to 500 degrees F below the gas temperature. Relatively small amounts of blade cooling, at constant gas temperature, give large increases in blade life. Dependence of rim cooling on heat-transfer coefficient, blade dimensions, and thermal conductivity is determined by a single parameter.
Contributing Partner: UNT Libraries Government Documents Department
Permallink:digital.library.unt.edu/ark:/67531/metadc65597/
An Experimental Investigation of NACA Submerged-Duct Entrances
Date: May 23, 1945
Creator: Frick, Charles W.
Description: The results of an investigation of submerged-duct entrances are presented. It is shown that this type of entrance possesses the following characteristics: 1) very high-critical-compressibility speeds throughout the range of high-speed inlet velocity ratios; 2) very low pressure losses for the air entering the duct at all inlet-velocity ratios; and, 3) low external drag. These characteristics are obtained by the proper shaping of the contour of the upstream approach to the submerged inlets and by proper alignment of the duct lip. Design data are presented and the application of these data to a specific high-speed fighter-airplane design is discussed.
Contributing Partner: UNT Libraries Government Documents Department
Permallink:digital.library.unt.edu/ark:/67531/metadc65007/
Wind-Tunnel Tests of a Portion of a PV-2 Helicopter Rotor Blade
Date: March 29, 1945
Creator: Kemp, William B., Jr.
Description: A portion of a PV-2 helicopter rotor blade has been tested in the 6- by 6-foot test section of the Langley stability tunnel to determine if the aerodynamic characteristics were seriously affected by cross flow or fabric distortion. The outer portion of the blade was tested as a reflection plane model pivoted about the tunnel wall to obtain various angles of cross flow over the blade. Because the tunnel wall acts as a plane of sy~try, the measured aerodynamic characteristics correspond to those of an airfoil having various angles of sweepforward and sweepback. Tests were made with the vents on the lower surface open and also with the vents sealed and the internal pressure held at -20 inches of water producing an internal pressure coefficient of -1.059. The change in contour resulting from the range of internal pressures used had very little effect on the aerodynamic characteristics of the blade. The test methods were considered to simulate inadequately the flow conditions over the rotor blade because the effects of cross flow were limited to conditions corresponding to sweep of the blade. The results indicated that this type of cross flow had only minor effects on the aerodynamic characteristics of the ...
Contributing Partner: UNT Libraries Government Documents Department
Permallink:digital.library.unt.edu/ark:/67531/metadc65602/
Tests of a 1/7-Scale Semispan Model of the XB-35 Airplane in the Langley 19-Foot Pressure Tunnel
Date: January 16, 1946
Creator: Teplitz, Jerome
Description: A 1/7 scale semispan model of the XB-35 airplane was tested in the Langley 10 foot pressure tunnel, primarily for the purpose of investigating the effectiveness of a leading-edge slot for alleviation of stick-fixed longitudinal instability at high angles of attack caused by early tip stalling and a device for relief of stick-free instability caused by elevon up-floating tendencies at high angles of attack. Results indicated that the slot was not adequate to provide the desired improvement in stick-fixed stability. The tab-flipper device provided improvement in stick-free stability abd two of the linkage combinations tested gave satisfactory variations of control force with airspeed for all conditions except that in which the wing-tip "pitch-control" flap was fully deflected. However, the improvement in control force characteristics was accompanied by a detrimental effect on stick-fixed stability because of the pitching moments produced by the elevon tab deflection.
Contributing Partner: UNT Libraries Government Documents Department
Permallink:digital.library.unt.edu/ark:/67531/metadc64054/
Wind-Tunnel Tests of a 1/6-Scale Model of Republic XF-12 Vertical Tail with Stub Fuselage and Stub Horizontal Tail
Date: June 2, 1945
Creator: MacLachlan, Robert
Description: A 1/6-scale model of the Republic XF-12 vertical tail with stub fuselage and stub horizontal tail was tested in the Langley stability tunnel to determine the aerodynamic characteristics of the model, The investigation included a study of the effects of boundarylayer thickness, rudder area, and cover-plate alinement on the aerodynamic characteristics. Tuft studies were made in the vicinity of the junction of the vertical and stub horizontal tails. The results of the investigation indicated that the flow in the vicinity of the junction of the vertical and stub horizontal tails was only slightly improved by the addition of a fillet. An increase in boundary-layer thickness produced a slight decrease in rudder effectiveness. The increase in lift of the combined rudders over that of the upper rudder alone was not proportional at low deflections and was approximately proportional at high deflections to the increase in rudder area. When the balance-chamber cover plates were bowed out, the change in rudder hinge moment with rudder angle was less negative. The variation of the lift coefficient with angle of attack and the variation, at small values of angle of attack, of rudder hinge-noment coefficient with angle of attack was approximately the same for all ...
Contributing Partner: UNT Libraries Government Documents Department
Permallink:digital.library.unt.edu/ark:/67531/metadc64933/
Wind-Tunnel Tests of a 1/5-Scale Semispan Model of the Republic XF-12 Horizontal Tail Surface
Date: January 1, 1945
Creator: Denaci, H. G.
Description: Wind-tunnel tests of a 1/5-scale semispan model of the Republic XF-12 horizontal tail surface equipped with an internally balanced elevator were conducted in the 6- by 6-foot test section of the Langley stability tunnel. The tests included measurements of the aerodynamic characteristics of the horizontal tail with and without a beveled trailing edge and also included measurements of the tab characteristics. The variation of the aerodynamic characteristics with boundary-layer conditions and leakage in the internal-balance chambers, measurements of the boundary-layer displacement thickness near the elevator hinge axis, and pressure distributions at the mean geometric chord were also obtained. The results showed that the hinge-moment characteristics of the elevator were critical to boundary-layer conditions and internal-balance leakage. Increasing the boundary-layer displacement thickness by use of roughness strips reduced the rate of change of elevator hinge moments with tab deflection by about 20 percent. The present horizontal tail appears to be unsatisfactory for longitudinal stability with power on, however, an increase in horizontal-tail lift effectiveness should correct this difficulty. The maneuvering stick force per unit acceleration will be extremely critical to minor variations of the elevator hinge moments if the elevator is linked directly to the stick.
Contributing Partner: UNT Libraries Government Documents Department
Permallink:digital.library.unt.edu/ark:/67531/metadc64935/
Aerodynamic Characteristics of Four Republic Airfoil Sections from Tests in Langley Two-Dimensional Low-Turbulence Tunnels
Date: September 27, 1945
Creator: Klein, Milton M.
Description: Four airfoils sections, designed by the Republic Aviation Corporation for the root and tip sections of the XF-12 airplane, were tested in the Langley two-dimensional low-turbulence tunnels to obtain their aerodynamic characteristics. Lift characteristics were obtained at Reynolds numbers of 3,000,000, 6,000,000, 9,000,000, and 14,000,000, whereas drag characteristics were obtained at Reynolds numbers of 3,000,000, 6,000,000, and 9,000,000. Pressure distributions were obtained for one of the root sections for several angles of attack at a Reynolds number of 2,600,000. Comparison of the root section that appeared best from the tests with the corresponding NACA 65-series section shows the Republic section has a higher maximum lift and higher calculated critical speeds, but a higher minimum drag. In addition, with standard roughness applied to the leading edge, the maximum lift of the Republic airfoil is lower than that of the NACA airfoil. Comparison of the Republic tip section with the corresponding NACA 65-series section shows the Republic airfoil has a lower maximum lift and a higher minimum drag than the NACA airfoil. The calculated critical speeds of the Republic section are slightly higher than those of the NACA section.
Contributing Partner: UNT Libraries Government Documents Department
Permallink:digital.library.unt.edu/ark:/67531/metadc64938/
Wind-Tunnel Tests of a 1/6-Scale Model of Republic XF-12 Vertical Tail Incorporating a De-Icing Air Duct
Date: January 1, 1945
Creator: MacLachlan, Robert
Description: A 1/6-scale model of the Republic XF-12 vertical tail with stub fuselage, stub horizontal tail, and a de-icing air duct was tested in the Langley stability tunnel. The investigation consisted of a study of the effects of the duct, with and without air flow, on the aerodynamic characteristics of the model. The model tested was a revision of a model previously tested in the Langley stability tunnel. The revised model differed from the original model in that it incorporated a de-icing air duct, included a dorsal fin, and had a larger stub fuselage. A comparison of data obtained form tests of the original and revised models was made. The results of the investigation indicated that the air duct had very little effect on the aerodynamic characteristics of the model. A small change occurred in the variation of rudder hinge-moment coefficient with angle of attack but it is believed that this change can be corrected by a properly applied spring tab.
Contributing Partner: UNT Libraries Government Documents Department
Permallink:digital.library.unt.edu/ark:/67531/metadc64934/
Vibration-response tests of a 1/5-scale model of the Grumman F6F airplane in the Langley 16-foot high-speed tunnel
Date: November 1, 1944
Creator: Regier, Arthur A
Description: None
Contributing Partner: UNT Libraries Government Documents Department
Permallink:digital.library.unt.edu/ark:/67531/metadc60875/