Search Results

open access

The Chelate Process: [Part] 5. Investigation in Horizontal Extractors

Description: The recovery of plutonium has been demonstrated in a laboratory countercurrent horizontal extractor using the TTA process. Using three extractive stages and two washing stages in each step, a recovery of 91 percent has been obtained in the chelation step and a recovery of 99.9+ percent in the de-chelation step. With five extractive stages, recoveries of 94-98 percent have been found for the chelation step.
Date: July 29, 1949
Creator: Hicks, T. E.; Rubin, B. & Vermeulen, T.
open access

Summary of the Research Progress Meeting of September 1, 1949

Description: The absolute excitation functions for the production of fission by charged particle bombardment in several substances were investigated at both high and low energies. The low energy work was done at the 60-inch Crocker cyclotron with alpha particles and deuterons, while the high energy work was done at the 184-inch cyclotron with alpha particles, deuterons, and protons.
Date: October 13, 1949
Creator: Wakerling, R. K. (Raymond Kornelious), 1914-
open access

Use of the Characteristics of Permalloy in Detecting a Predetermined Value of Magnetic Field or Current in a Time-Varying Electromagnet: 1/4 Scale Bevatron Operating Model, Magnetic Field Strength-Magnet Current Correspondence

Description: In programming the sequence of events in the operational cycle of the bevatron, certain devices must be triggered at specific values of magnetic field strength in the gap. It is desirable that the time-jitter, which corresponds to field jitter, of the tirggering pulses be small. In the synchrotron this is done with peaking strips which are located in the fringing field of the gap.
Date: March 24, 1949
Creator: Richardson, R. E.; Shuey, R. L.; Younkin, R. & Stephan, W. J.
open access

Method of Operation of the Permeameter

Description: In H measurements, the measured flux-linkage change represents twice the value of H to be plotted. In B measurements the bucking coil links flux equal to the air-flux in the B-measuring coils. The measured flux change therefore corresponds to twice the flux of intrinsic magnetization in the sample.
Date: January 21, 1949
Creator: Richardson, R. E.
open access

The Distribution of the Positive-Negative Ratio for Mesons

Description: Positive and negative mesons produced in a common target in the cyclotron are received in two photographic plates. In the magnetic field of the cyclotron, negatives are deflected to one plate, positives to the other. The mesons must pass through an absorber before entering the plates in order to be observable.
Date: December 14, 1949
Creator: Rankin, Bayard, 1924-
Back to Top of Screen