The SNAP II Power Conversion System. Topical Report No. 4. Turbine Design and Testing
Description:
SNAP II is the designation for a 3 KW nuclear auxiliary power unit to be used in a satellite vehicle. The SNAP II system consists of a reactor heat source, a mercury Rankine engine and an alternator. A two stage, full admission, axial flow turbine was chose for the APU application. Design details and test results are presented in this report. This work was performed under a subcontract to to Atomics International as part of the Atomic Energy Commission Contract No. AT(11-1)-GEN-8.
Date:
January 18, 1960
Creator:
Poulos, Earnest N. & Forman, Edward R.