Search Results

An Improved Recording Anemometer System
Recent developments in the field of photoconductive devices made possible the simplification and attendant improvement of the recording anemometer system used with the portable meteorological mast. The purpose of the work was to produce a simple, reliable recording anemometer system compatible with the project's existing instrumentation. Of primary importance was reduction of maintenance without loss of accuracy. This report discusses some of the factors considered in the design of the system, describes in detail the electronic circuitry and mechanical components, and presents some performance data. The data obtained from a twenty-four hour trial run indicates that the system has fulfilled the requirements.
A Dripless Transfer Pipette for Radiochemical Operations
Transfer operations of highly radioactive solutions by the normal transfer pipette leads in most instances to a spread of contamination in the shielded facility. In the dripless pipette, the solution is held in the reservoir by the use of the siphon principle.
Back to Top of Screen