Search Results

open access

Susceptibility of a digital turbine control system to IEEE 802.11 compliant emissions.

Description: Within the nuclear industry, there have been numerous instances of radio transmissions interfering with sensitive plant equipment. Instances documented vary from minor instrument fluctuations to major plant transients including reactor trips. With the nuclear power industry moving toward digital technologies for control and reactor protection systems, concern exists regarding their potential susceptibility to contemporary wireless telecommunications technologies. This study evaluates the suscep… more
Date: December 2003
Creator: Carter, Clinton E.
open access

Cost Savings Realized Through Proper Sizing of an Excessive Instrument Air System.

Description: The purpose of this research was to determine if installing a smaller air compressor could reduce the electrical usage of a large semiconductor manufacturing plant. A 200 horsepower Atlas Copco compressor was installed with the existing 500 horsepower Ingersoll-Rand compressors. Testing was conducted during the regular manufacturing process at MEMC Southwest in Sherman, Texas. Analysis of the data found that installing the new compressor could reduce electrical consumption. The study also found… more
Date: December 2003
Creator: Condron, Ewell D.

Increasing the Dynamic Range of Audio THD Measurements Using a Novel Noise and Distortion Canceling Methodology

Description: The objective of this study was to determine how a new experimental methodology for measuring Total-Harmonic-Distortion (THD) of operational amplifiers functioned when compared with two standard methodologies, and whether the new methodology offers any improvement in noise floor and dynamic range along with distortion canceling of the sine-wave source used in the testing. The new methodology (THD) is being tested against two standard methodologies: Spectral Analysis using a tuned receiver type … more
Access: Restricted to UNT Community Members. Login required if off-campus.
Date: May 2003
Creator: Dunipace, Richard Alan

Characterization of Iron Oxide Deposits Formed at Comanche Peak Steam Electric Station

Description: The presence of deposits leading to corrosion of the steam generator (SG) systems is a major contributor to operation and maintenance cost of pressurized water reactor (PWR) plants. Formation and transport of corrosion products formed due to the presence of impurities, metallic oxides and cations in the secondary side of the SG units result in formation of deposits. This research deals with the characterization of deposit samples collected from the two SG units (unit 1 and unit 2) at Comanche P… more
Access: Restricted to the UNT Community Members at a UNT Libraries Location.
Date: May 2003
Creator: Namduri, Haritha
Back to Top of Screen