Search Results

Spatial and Temporal Patterns of Areal and Volumetric Phytoplankton Productivity of Lake Texoma
Phytoplankton productivity of Lake Texoma was measured for one year from August 1999 to August 2000 for four stations, using the oxygen change method and laboratory incubation. Mean values of the photosynthetic parameters, PBmax and alphaB ranged from 4.86 to 46.39 mg O2.mg Chl-1.hr-1 for PBmax and 20.06 to 98.96 mg O2.mg Chl-1.E-1.m2 for alphaB. These values were in the range to be expected for a highly turbid, temperate reservoir. Estimated gross annual areal productivity ranged from 594 g C.m2.yr-1 (P.Q. = 1.2), at a station in the Washita River Zone to 753 g C.m2.yr-1 at a station in the Red River Zone, of the reservoir. Gross annual areal productivity at Station 17, in the Main Lake Zone, was 708 g C.m2.yr-1. Gross areal and volumetric productivity showed distinct seasonal variation with Photosynthetically Available Radiation (PAR) and temperature. Trophic status estimated on a station-by-station basis, using net productivity values derived from gross productivity and respiration estimates, was mesotrophic for all the stations, though one station approached eutrophy. Net productivity values ranged from 0.74 to 0.91 g C. m-2.d-1. An algal bioassay conducted at two stations in August 2000, revealed that phosphorus was most likely the nutrient limiting photosynthesis at both these stations, although the more turbid riverine station was primarily light-limited.
Characterizing the Municipal Solid Waste Stream in Denton, Texas
Forty-two commercially collected dumpsters from Denton’s Municipal Solid Waste Stream were emptied, sorted and weighed to characterize the material types and make preliminary recycling policy recommendations. The general composition of Denton’s solid waste stream was not significantly different from the composition of the nation’s solid waste stream. Fifty-eight percent of the observed waste stream was recyclable. Paper made up the largest portion of recyclable materials and the "grocery" source category had more paper than any of the other five categories. Based on these findings, an incrementally aggressive approach is recommended to reduce certain types of wastes observed in the waste stream. This would include a Pay-As-You-Throw Program followed by an Intermediate Processing Center that can be converted to a Materials Recovery Facility.
Plankton Community Response to Dechorination of a Municipal Effluent Discharged into the Trinity River
Chorine is used by the Village Creek Waste Water Treatment Plant to kill pathogenic microorganisms prior to discharge of the effluent into the Trinity River. The residual chlorine in the river impacted aquatic life prompting the U.S. Environmental Protection Agency in December 1990 to require dechlorination using sulfur dioxide. One pre-dechlorination and four post-dechlorination assessments of phytoplankton, periphyton, and zooplankton communities were conducted by the Institute of Applied Sciences at the University of North Texas. Dechlorination had no effect on the phytoplankton community. The periphyton community exhibited a shift in species abundance with a more even distribution of organisms among taxa. No change occurred in zooplankton species abundance, however, there was a decrease in zooplankton density following dechlorination.
Monitoring Watershed Health in the Upper Trinity River Basin, North Central Texas
This study conducts watershed analysis using biological and geo-spatial techniques. Incorporating landscape features with biological attributes has been shown to be an effective method of monitoring environmental quality within watersheds. In situ biomonitoring using the Asiatic Clam, Corbicula fluminea, habitat suitability, and water quality data were evaluated for their potential to describe ecological conditions in agricultural and urban areas within the Upper Trinity River watershed. These data were analyzed with GIS to identify effects of land use on ecological conditions. C. fluminea downstream of point source effluents was effective detecting in-stream toxicity. Ambient toxicity appears to have improved in the Trinity, although urban influences limit aspects of aquatic life. No association between habitat quality and land use was identified.
Pretreatment Optimization of Fiberglass Manufacturing Industrial Wastewater
Wastewater effluent produced in the fiberglass manufacturing industry contains a significant amount of total suspended solids. Environmental regulations require pretreatment of effluent before it is discharged to the municipal wastewater treatment plant. Chemical precipitation by coagulation and flocculation is the method of pretreatment used at the Vetrotex CertainTeed Corporation (VCT). A treatability study was conducted to determine conditions at which the VCT Wastewater Pretreatment Plant could operate to consistently achieve a total suspended solids concentration ≤ 200-mg/L. Jar tests varied pH, polymer dosage, and ferric sulfate dosage. Total suspended solids and turbidity were measured to evaluate treatment performance. The data were used to determine an optimum set of conditions under project guidelines. Of twelve polymers screened, BPL 594 was selected as the most effective polymer. For cost efficiency in the wastewater pretreatment operation, recommendations suggested that treatment chemical injection be electronically controlled according to turbidity of the treated effluent.
Interspecific Competition Between Hygrophila polysperma and Ludwigia repens, Two Species of Importance in the Comal River, Texas
Hygrophila polysperma is a plant native to Asia that has been introduced into the Comal River, TX and is thriving while Ludwigia repens, a species native to the river appears to be declining. Both plants have similar morphologies and occupy similar habitats in the river. Two plant competition experiments were conducted to examine the competitive interactions between the two species. First, an experimental design was developed in which established Ludwigia plants were 'invaded' by sprigs of Hygrophila to determine if established Ludwigia populations would be negatively impacted by invasion. The second experiment focused on establishment and growth of sprigs of each species under three competition scenarios. Results show that the continued growth of well-established Ludwigia plants was significantly depressed by the invasion of Hygrophila in comparison with those that had not been invaded. Furthermore, the growth of Hygrophila sprigs was uninhibited by the presence of Ludwigia, but the presence of Hygrophila negatively impacted the growth of Ludwigia sprigs. There was no difference in the growth of Hygrophila sprigs whether planted alone, with Ludwigia sprigs or even if planted into stands of established Ludwigia.
Environmental Factors Influencing Chlorophyll-a Concentrations in Lake Texoma
An analysis of algal biomass measured by chlorophyll-a concentration in Lake Texoma was performed as a part of a monitoring program to develop baseline environmental data in order to detect the potential effects of engineered changes in chloride concentrations in the reservoir. This portion of the research project focused on two main research objectives. The first objective was evaluating the effect of sampling strategy on the ability to adequately reflect standing crop estimates and trends in algal biomass. Two sampling regimes utilizing replication of three versus ten samples were applied and then analyzed using a minimum detectable difference algorithm to determine the necessary magnitude of replication to represent the variation in the metric. Chlorophyll-a distribution was analyzed for zonation patterns expected in a river-run reservoir to establish the importance of representative sampling of river, transition and main lake zones of the reservoir for management decisions and trophic characterization.
An Assessment of Storm Water Toxicity from the Dallas/Fort Worth Metroplex and Denton, Texas
With the advent of national storm water regulations, municipalities with populations greater than 100,000 are required to obtain National Pollutant Discharge Elimination System Permits (NPDES) for storm water discharges. In addition to the sampling required for the permit process, the City of Fort Worth contracted with the University of North Texas' Institute of Applied Sciences to conduct acute toxicity testing using Pimephales prcmelas and Ceriodaphnia dubia on storm water samples received from the Dallas/Fort Worth Metroplex. A Toxicity Identification Evaluation (TIE) was performed on four samples that exhibited acute toxicity to C. dubia. High levels of metals as well as diazinon were some of the probable toxicants found.
Assessment of Radio-Tagged Grass Carp (Ctenopharnygodon idella) Dispersion, Vegetation, and Temperature Preferences in North Lake Reservoir
Twenty-nine (Group One, June 8,1995) grass carp (Ctenopharyngodon idella) and five (Group Two, April 18, 1996) grass carp were radio-tagged to monitor movement patterns and habitat preferences on North Lake, a 335 hectare multi-use reservoir located in Irving, Texas. Overall fish mean Average Daily Movement (ADM) rates were 49.2 meters/day (during Half One, 6/8/95-11/30/95) and 5.3 meters/day (during Half Two, 12/14/95-6/6/96). Aquatic macrophtye distribution data were obtained. Radio-tagged grass carp were located in Hydrilla verticillata infested areas increasingly throughout the study, however, percent frequency of Hydrilla along 15 transects did not decrease. Radio-transmitters were equipped with temperature-sensors (10-35 Celsius range). Results indicated that radio-tagged grass carp showed no avoidance of areas of North Lake with elevated water temperatures. Radio-tagged grass carp dispersed quickly from stocking point, then moved into littoral areas infested with Hydrilla. After an initial movement period, most fish remained in a localized area.
Assessing the Spatial and Temporal Distribution of MTBE and BTEX Compounds in Lake Lewisville, Texas February 1999 - February 2000
The spatial and temporal distribution of Methyl Tertiary-Butyl Ether (MTBE) and BTEX (Benzene, Toluene, Ethylbenzene, Xylenes) compounds were assessed in a multipurpose reservoir, Lake Lewisville, Texas between February 1999 and February 2000. Concentrations of MTBE ranged from 0.0 - 16.7 mg/L. Levels of MTBE in the lake were related to watercraft. BTEX concentrations were never detected above 2.0 mg/L during the sampling period. Finished drinking water from Denton and the Upper Trinity Regional Water District (UTRWD) Treatment Plants were also tested for MTBE and BTEX. MTBE and BTEX were not detected in UTRWD water samples. Denton's finished water samples never exceeded 2.2 mg/L for MTBE and BTEX was not detected except for one replicate of 1.1 mg/L toluene.
Recovery of the Fish Population of a Municipal Wastewater Dominated, North Texas Creek After a Major Chlorine Disturbance
This study evaluated the effects of a major chlorine disturbance on fish communities in Pecan creek by the City of Denton's Pecan Creek Water Reclamation Plant. Fish communities in Pecan Creek were sampled using a depletion methodology during February, April, July, and November, 1999. February and April sampling events showed that the fish communities were severely impacted by the chlorine. Sampling during July and November showed fish communities recovered in Pecan Creek. The first-twenty minutes of shocking and seining data were analyzed to mirror an equal effort methodology. This methodology was compared to the depletion methodology to see if the equal effort methodology could adequately monitor the recovery of Pecan Creek after the chlorine disturbance. It was determined that the equal effort methodology was capable of monitoring the recovery of Pecan Creek, but could not accurately represent the fisheries community as well as the depletion method. These data using the twenty-minute study were compared to a previous study. Results of this study were similar to those found in a previous study, although fish communities were more severely impacted and took longer to recover.
Simulating Thermal and Chemical Spills in Coupled Cooling Reservoirs
Hot water discharges and potential chemical spills are factors that threaten water quality in cooling reservoirs of chemical and power plants. In this thesis, three models are used to analyze the impact of these factors in a particular case study.
Assessing Regional Gully Erosion Risk: A Remote Sensing and Geographic Information Systems Approach
Gully erosion has been established as a major source of sediment pollution in the upper Trinity River watershed in north-central Texas. This fact, along with a lack of models appropriate for a large-area gully erosion analysis established a need for a gully erosion study in the upper Trinity basin. This thesis project attempted to address this need by deriving an index indicative of gully erosion risk using remote sensing and geographic information systems (GIS) methodology. In context of previous field studies, the coarse spatial resolution of the input GIS data layers presented a challenge to prediction of gully prone areas. However, the remote sensing/GIS approach was found to provide useful reconnaissance information on gully risk over large areas.
The Tarrant County Atlas for Planning: A Geographic Information System for Open Space Design
This project demonstrates the construction of a land planning geographic information system (GIS) for Tarrant County, and explores how the technology could be used to select sites for a county wide open space preservation plan. As Texas' Tarrant County continues to undergo rapid change due to growth and expansion, the need for proactive, resourceful community planning is greater than ever. One crucial issue facing the region is how to preserve open areas that serve the county's citizens' ecological, recreational, cultural and economic needs. In order to assess how much open space is needed and which sites should be considered for special attention, large amounts of varied spatial information must be analyzed. The answer to effectively dealing with such data sets is a geographic information system (GIS) that stores all pertinent data digitally and allows for its manipulation through use of a computer software package. This project demonstrates the construction of a land planning GIS for Tarrant County, and explores how the technology could be used to select sites for a county wide open space preservation plan.
Estimated Extent and Fate of Chlorinated Solvent Contamination in the Soil of the Naval Air Station, Dallas, Texas
This thesis estimates the spatial extent of chlorinated solvent contamination of the soil at the Naval Air Station, Dallas, then estimates the fate and transport of these contaminants, over time, using the Soil Transport and Fate database and the Vadose-Zone Interactive Processes (VIP) modeling software. Geostatistical analysis identifies two areas with serious chlorinated solvent contamination. Fate and transport modeling estimates that this contamination will degrade and disperse from the soil phase to below regulatory limits within one year, although there is a risk of groundwater contamination. Contaminants are estimated to persist in the water and air phases of the soil. Further sampling is recommended to confirm the results of this study.
An Evaluation of Fish and Macroinvertebrate Response to Effluent Dechlorination in Pecan Creek
This study evaluated the effects of chlorinated effluent discharged from the City of Denton, Texas' wastewater treatment plant on Pecan Creek's fish and macroinvertebrate assemblages, and their recovery upon dechlorination. A baseline of ecological conditions was established while chlorine was present in the effluent (June 1993- October 1993), and was evaluated again after dechlorination with sulfur dioxide (October 1993-August 1994). In situ Asiatic clam and fathead minnow ambient toxicity tests, and fish and macroinvertebrate collections were used to establish this baseline for comparison to post-dechlorination results.
Back to Top of Screen