Report containing information regarding He4 vapor pressure measurement as of 1958, the recent history of the vapor pressure temperature scale, and a series of tables containing these measurements.
Report providing detail measurements and percentages in charts, using three statistical parameters, for amplitude-probability distributions of atmospheric radio noise.
Report that briefly describes many of the models of crystal and molecular structures which have appeared in the literature, and presents a bibliography of the publications, grouped according to model types, which describe the models in more detail.
From Abstract: "The methods used at the National Bureau of Standards in calibrating line standards of length and measuring tapes submitted for standardization are outlined. The equipment used is described briefly. There is a discussion of some considerations that should be given as to whether or not a standard should be submitted to the Bureau."
From Introduction: "This Monograph has as its purpose the compilation and analysis of the extensive radio refractive index data available within the Central Radio Propagation Laboratory of the National Bureau of Standards. This will be accomplished by presenting both tabulations of basic data for specific locations and charts for interpolation to any location."
Report issued by the Bureau of Standards over studies on the importance of conductive flooring in hospitals. Types of conductive flooring are compared, and tested. The methods and results are presented, and discussed. This report includes tables, illustrations, and photographs.
From Abstract: "This Monograph has been prepared to give an understanding of heat treatment principally to those unacquainted with this subject. This Monograph has been prepared to answer such inquiries and to give in simplified form a working knowledge of the basic theoretical and practical principles involved in the heat treatment of iron and steel."
From Introduction: "The data are presented with the idea that an engineer who is making initial calculations on equipment for operation at cryogenic temperatures is more interested in obtaining quickly a definite figure that he in evaluating the experimental data given in several detailed reports on the same material. The graphs and tables presented here, consequently, represent an attempt by the authors to perform evaluation of data which have appeared in the literature and to present the design engineer with the result."
From Abstract: "Sources of error in measuring pressures are described in considerable detail, particularly for portable instruments including scale, temperature , gravity, capillarity, vacuum errors and return gas column. Methods of minimizing those errors and of making the corrections, including extensive tables, are presented."
From Abstract: "Several dynamic determinations have been made of the constants of quartz. Most of these determinations do not take into account the piezoelectric effect; those that do, suffer from certain deficiencies which are discussed in this paper."
Report of the annual conference on weights and measures, hosted by the U.S. National Bureau of Standards in Washington D.C. It includes conference proceedings, a list of attendees, information about committees and officers, and other reports or commentaries discussed at the meetings.
Report discussing wavelengths and estimated intensities in electrodeless lamp and spark sources presented for 15121 lines of ThI, ThII, ThIII, and ThIV in the spectral range from 2000 to 11550 A. Also contains tables of previously published interferometric values.
From Introduction: "This Monograph describes methods and apparatus used at the National Bureau of Standards in connection with several series of investigations of heats of combustion of aircraft fuels [4, 5, 6, 7]."
From Introduction: "The present paper contains detailed descriptions of the methods used in calculating both the elastic constants and the statistical parameters. These detailed descriptions have been included for two reasons: (1) To leave no doubt as to the exact procedure, and (2) to act as a guide to other workers who might wish to make similar determinations."
Report giving tables of the specific heat, cp, and the enthalpy of 28 metals, 3 alloys, 8 other inorganic substances, and 8 organic substances in the temperature range, 1º to 300º K.
From Forward: "Although the first paper in this volume describes the general aspects of the technical management of the program, it is important to emphasize that much of success and productivity of this program stemmed from the sympathetic understanding of its basic viewpoint by both the Department of Defense and the National Bureau of Standards."
From Extension of Tables: "Because of its range and size, this table of wavenumbers is in two volumes, Volume I presenting wavenumbers for all wavelengths between 2000 and 7000 A, and Volume II giving wave-numbers for all wavelengths from 7000 A to 10000000 A=1 mm. In some cases Volume I may suffice for ionic spectra, and in others Volume II may be adequate for molecular spectra, but in general both volumes will needed to cover the entire range of spectral wavelengths measured in standard air."
Report discussing "A two-volume table for converting wavelengths in standard air to wavenumbers in vacuum. Wave-numbers are given to the nearest 0.001 K (cm^-1) for wavelengths from 2000 to 7000 A in volume 1, and 7000 A to 1000 m in volume II."
Report discussing how solids subjected to non-uniform temperature change develop internal stresses determined by, (1) the temperature distribution within the solid, and (2) certain physical constants of the material. For two varieties of heating, the equations determining stress have been put in convenient form for practical use, and tables of certain temperature functions show how to determine stresses in a slab, in a cylinder, or in a sphere subjected to either of two modes of heating. The temperature-distribution tables independently provide a useful means for the ready estimation of temperature gradients.
Reports discussing bands of common gases that have been tabulated and remeasured wherever necessary from 2 to 16 microns to obtain an accuracy of about 0.03 cm-1 throughout the region and to provide good calibrating points at frequent intervals. Some 600 rotation-vibration lines are illustrated in 20 spectrograms and wavenumbers are listed in companion tables with considerable intercomparison with worthy data obtained in other laboratories. The absorption bands were remeasured or calibrated by using either a precisely graduated grating circle or standard atomic lines with the fringe system formed by a Fabry-Perot interferometer. Characteristic features of the individual bands are discussed briefly and references to other publications are given. The substances used for calibration include H2O, CO2, CO, HCl, HBr, NH3, C2H2, CH4, N2O, and polystyrene film.
This dialog allows you to filter your current search.
Each of the Serial/Series Titles listed note their name and the number of records that will be limited down to if you choose that option.
This dialog allows you to filter your current search.
Each of the World Regions listed note their name and the number of records that will be limited down to if you choose that option.
This dialog allows you to filter your current search.
Each of the Countries listed note their name and the number of records that will be limited down to if you choose that option.
This dialog allows you to filter your current search.
Each of the Months listed note their name and the number of records that will be limited down to if you choose that option.
The list can be sorted by name or the count.
This dialog allows you to filter your current search.
Each of the Days listed note their name and the number of records that will be limited down to if you choose that option.
The list can be sorted by name or the count.