You limited your search to:

  Partner: UNT Libraries Government Documents Department
 Serial/Series Title: NACA Memorandum Report
 Collection: National Advisory Committee for Aeronautics Collection
Wind-Tunnel Tests of a 1/5-Scale Semispan Model of the Republic XF-12 Horizontal Tail Surface

Wind-Tunnel Tests of a 1/5-Scale Semispan Model of the Republic XF-12 Horizontal Tail Surface

Date: January 1, 1945
Creator: Denaci, H. G.
Description: Wind-tunnel tests of a 1/5-scale semispan model of the Republic XF-12 horizontal tail surface equipped with an internally balanced elevator were conducted in the 6- by 6-foot test section of the Langley stability tunnel. The tests included measurements of the aerodynamic characteristics of the horizontal tail with and without a beveled trailing edge and also included measurements of the tab characteristics. The variation of the aerodynamic characteristics with boundary-layer conditions and leakage in the internal-balance chambers, measurements of the boundary-layer displacement thickness near the elevator hinge axis, and pressure distributions at the mean geometric chord were also obtained. The results showed that the hinge-moment characteristics of the elevator were critical to boundary-layer conditions and internal-balance leakage. Increasing the boundary-layer displacement thickness by use of roughness strips reduced the rate of change of elevator hinge moments with tab deflection by about 20 percent. The present horizontal tail appears to be unsatisfactory for longitudinal stability with power on, however, an increase in horizontal-tail lift effectiveness should correct this difficulty. The maneuvering stick force per unit acceleration will be extremely critical to minor variations of the elevator hinge moments if the elevator is linked directly to the stick.
Contributing Partner: UNT Libraries Government Documents Department
Wind-Tunnel Tests of a 1/6-Scale Model of Republic XF-12 Vertical Tail Incorporating a De-Icing Air Duct

Wind-Tunnel Tests of a 1/6-Scale Model of Republic XF-12 Vertical Tail Incorporating a De-Icing Air Duct

Date: January 1, 1945
Creator: MacLachlan, Robert
Description: A 1/6-scale model of the Republic XF-12 vertical tail with stub fuselage, stub horizontal tail, and a de-icing air duct was tested in the Langley stability tunnel. The investigation consisted of a study of the effects of the duct, with and without air flow, on the aerodynamic characteristics of the model. The model tested was a revision of a model previously tested in the Langley stability tunnel. The revised model differed from the original model in that it incorporated a de-icing air duct, included a dorsal fin, and had a larger stub fuselage. A comparison of data obtained form tests of the original and revised models was made. The results of the investigation indicated that the air duct had very little effect on the aerodynamic characteristics of the model. A small change occurred in the variation of rudder hinge-moment coefficient with angle of attack but it is believed that this change can be corrected by a properly applied spring tab.
Contributing Partner: UNT Libraries Government Documents Department
Wind-Tunnel Tests of a 1/6-Scale Model of Republic XF-12 Vertical Tail with Stub Fuselage and Stub Horizontal Tail

Wind-Tunnel Tests of a 1/6-Scale Model of Republic XF-12 Vertical Tail with Stub Fuselage and Stub Horizontal Tail

Date: June 2, 1945
Creator: MacLachlan, Robert
Description: A 1/6-scale model of the Republic XF-12 vertical tail with stub fuselage and stub horizontal tail was tested in the Langley stability tunnel to determine the aerodynamic characteristics of the model, The investigation included a study of the effects of boundarylayer thickness, rudder area, and cover-plate alinement on the aerodynamic characteristics. Tuft studies were made in the vicinity of the junction of the vertical and stub horizontal tails. The results of the investigation indicated that the flow in the vicinity of the junction of the vertical and stub horizontal tails was only slightly improved by the addition of a fillet. An increase in boundary-layer thickness produced a slight decrease in rudder effectiveness. The increase in lift of the combined rudders over that of the upper rudder alone was not proportional at low deflections and was approximately proportional at high deflections to the increase in rudder area. When the balance-chamber cover plates were bowed out, the change in rudder hinge moment with rudder angle was less negative. The variation of the lift coefficient with angle of attack and the variation, at small values of angle of attack, of rudder hinge-noment coefficient with angle of attack was approximately the same for all ...
Contributing Partner: UNT Libraries Government Documents Department
Wind-Tunnel Tests of a Portion of a PV-2 Helicopter Rotor Blade

Wind-Tunnel Tests of a Portion of a PV-2 Helicopter Rotor Blade

Date: March 29, 1945
Creator: Kemp, William B., Jr.
Description: A portion of a PV-2 helicopter rotor blade has been tested in the 6- by 6-foot test section of the Langley stability tunnel to determine if the aerodynamic characteristics were seriously affected by cross flow or fabric distortion. The outer portion of the blade was tested as a reflection plane model pivoted about the tunnel wall to obtain various angles of cross flow over the blade. Because the tunnel wall acts as a plane of sy~try, the measured aerodynamic characteristics correspond to those of an airfoil having various angles of sweepforward and sweepback. Tests were made with the vents on the lower surface open and also with the vents sealed and the internal pressure held at -20 inches of water producing an internal pressure coefficient of -1.059. The change in contour resulting from the range of internal pressures used had very little effect on the aerodynamic characteristics of the blade. The test methods were considered to simulate inadequately the flow conditions over the rotor blade because the effects of cross flow were limited to conditions corresponding to sweep of the blade. The results indicated that this type of cross flow had only minor effects on the aerodynamic characteristics of the ...
Contributing Partner: UNT Libraries Government Documents Department
Wind-tunnel tests of the 0.15-scale powered model of the Fleetwing XBTK-1 airplane : lateral stability and control

Wind-tunnel tests of the 0.15-scale powered model of the Fleetwing XBTK-1 airplane : lateral stability and control

Date: July 1, 1945
Creator: Silvers, H Norman
Description: None
Contributing Partner: UNT Libraries Government Documents Department
Wind-Tunnel Tests of the 0.15-Scale Powered Model of the Fleetwings XBTK-1 Airplane : Longitudinal Stability and Control

Wind-Tunnel Tests of the 0.15-Scale Powered Model of the Fleetwings XBTK-1 Airplane : Longitudinal Stability and Control

Date: May 1, 1945
Creator: Boykin, Rebecca I.
Description: An investigation was made of the static longitudinal stability, and control and stall characteristics of XBTK-1 dive bomber. Results indicate that the longitudinal stability will probably be satisfactory for all contemplated flight conditions at the rear-most CG location with elevator both fixed and free. Power effects were small. Sufficient elevator control will be available to trim in any flight condition above the ground. Increasing the slotted flap deflection above 30 degrees only slightly increased the max. lift coefficient.
Contributing Partner: UNT Libraries Government Documents Department
FIRST PREV 15 16 17 18 19 NEXT LAST