Abstract: The Dark Energy Survey Camera focal plane array will consist of 62 2k x 4k CCDs with a pixel size of 15 microns and a silicon thickness of 250 microns for use at wavelengths between 400 and 1000 nm. Bare CCD die will be received from the Lawrence Berkeley National Laboratory (LBNL). At the Fermi National Accelerator Laboratory, the bare die will be packaged into a custom back-side-illuminated module design. Cold probe data from LBNL will be used to select the CCDs to be packaged. The module design utilizes an aluminum nitride readout board and spacer and an Invar …
continued below
Publisher Info:
Fermi National Accelerator Laboratory (FNAL), Batavia, IL
Place of Publication:
Batavia, Illinois
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this article.
Follow the links below to find similar items on the Digital Library.
Description
Abstract: The Dark Energy Survey Camera focal plane array will consist of 62 2k x 4k CCDs with a pixel size of 15 microns and a silicon thickness of 250 microns for use at wavelengths between 400 and 1000 nm. Bare CCD die will be received from the Lawrence Berkeley National Laboratory (LBNL). At the Fermi National Accelerator Laboratory, the bare die will be packaged into a custom back-side-illuminated module design. Cold probe data from LBNL will be used to select the CCDs to be packaged. The module design utilizes an aluminum nitride readout board and spacer and an Invar foot. A module flatness of 3 microns over small (1 sqcm) areas and less than 10 microns over neighboring areas on a CCD are required for uniform images over the focal plane. A confocal chromatic inspection system is being developed to precisely measure flatness over a grid up to 300 x 300 mm. This system will be utilized to inspect not only room-temperature modules, but also cold individual modules and partial arrays through flat dewar windows.
This article is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
Derylo, Greg; Diehl, H. Thomas & Estrada, Juan.0.25mm-Thick CCD Packaging for the Dark Energy Survey Camera Array,
article,
2006-06~;
Batavia, Illinois.
(https://digital.library.unt.edu/ark:/67531/metadc887388/:
accessed April 24, 2024),
University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu;
crediting UNT Libraries Government Documents Department.