This document is a March 1949 Ad Interim Report on the development of a high-speed, low-sensitivity calorimeter at the Mound Laboratory. This calorimeter is a zero-compensating, thermocouple, twin type. The outside diameter of the aluminum tubing was machined for a slip fit into the glass test tube. Prior to assembling in the test tube, an aluminum plug was pressed in it midway from the ends. A groove was also milled on the outside down to the plug, and a copper-constantan thermocouple was secured in the groove after assembly. A single layer of aluminum foil was used to reduce radiation effects, …
continued below
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this report.
Follow the links below to find similar items on the Digital Library.
Description
This document is a March 1949 Ad Interim Report on the development of a high-speed, low-sensitivity calorimeter at the Mound Laboratory. This calorimeter is a zero-compensating, thermocouple, twin type. The outside diameter of the aluminum tubing was machined for a slip fit into the glass test tube. Prior to assembling in the test tube, an aluminum plug was pressed in it midway from the ends. A groove was also milled on the outside down to the plug, and a copper-constantan thermocouple was secured in the groove after assembly. A single layer of aluminum foil was used to reduce radiation effects, and stray air currents were excluded with a cotton plug. The two arms of the calorimeter were placed in a three-liter beaker filled with water. The constantan leads of the two thermocouples were soldered together to make them compensating. The copper leads were connected to a L & N potentiometer, and a L & N galvanometer was also used. The potentiometer-galvanometer circuit was so connected that before each reading of the EMF of the thermocouples, the thermal EMF in the circuit could be accounted for. The galvanometer was then mounted on a heavy brass plate. The data show that when the galvanometer is suitably mounted, it can be used to measure samples of from 50 to 75 curies with a precision of plus or minus one percent. The calorimeter also comes into equilibrium within 20 minutes. It is planned to study the apparatus to see whether the potentiometer can be dispensed with. It is possible that a direct measurement can be made with a suitable galvanometer, scale, and focusing lamp.
This report is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
Haring, M. M.A high-speed low-sensitivity calorimeter for high activity (Ad Interim Report),
report,
March 2, 1949;
United States.
(https://digital.library.unt.edu/ark:/67531/metadc619738/:
accessed March 28, 2024),
University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu;
crediting UNT Libraries Government Documents Department.