Ultrafast Laser Sampling of a Plant Tissue and ion Conductivity Measurement for Investigation of Light Stress Generation Mechanisms

PDF Version Also Available for Download.

Description

In this study we applied ultra-short laser pulses on a biological sample (Arabidopsis), in order to cut it precisely in a square pattern and subsequently use it for studying stress generation mechanisms. For this purpose, we utilized femtosecond laser pulses at 100 fs pulse width and 80 MHz repetition rate. We took two processing parameters into consideration such as laser power, laser exposure time which is related to the stage speed. Therefore, we were able to find the laser optimum conditions for ablation of biological tissues. The mutant and wildtype (control) obtained from laser cutting with a size of 500 … continued below

Physical Description

v, 58 p. : ill.

Creation Information

Abtahi, Seyed Ali August 2010.

Context

This thesis is part of the collection entitled: UNT Theses and Dissertations and was provided by the UNT Libraries to the UNT Digital Library, a digital repository hosted by the UNT Libraries. It has been viewed 568 times. More information about this thesis can be viewed below.

Who

People and organizations associated with either the creation of this thesis or its content.

Chairs

Committee Member

Publisher

Rights Holder

For guidance see Citations, Rights, Re-Use.

  • Abtahi, Seyed Ali

Provided By

UNT Libraries

The UNT Libraries serve the university and community by providing access to physical and online collections, fostering information literacy, supporting academic research, and much, much more.

Contact Us

What

Descriptive information to help identify this thesis. Follow the links below to find similar items on the Digital Library.

Description

In this study we applied ultra-short laser pulses on a biological sample (Arabidopsis), in order to cut it precisely in a square pattern and subsequently use it for studying stress generation mechanisms. For this purpose, we utilized femtosecond laser pulses at 100 fs pulse width and 80 MHz repetition rate. We took two processing parameters into consideration such as laser power, laser exposure time which is related to the stage speed. Therefore, we were able to find the laser optimum conditions for ablation of biological tissues. The mutant and wildtype (control) obtained from laser cutting with a size of 500 µm × 500 µm were directly transferred (in-situ with laser cutting) into a microfabricated chamber containing ~500 nanoliters deionized water for measuring ion conductivity. The ion conductivity is a signature of cell-death mechanisms caused by various stresses. A light with intensity of 100 µmol was exposed to the samples for 2 hours and 20 minutes as a source of stress. A quantitative electrical analysis with high accuracy was assured by utilizing a microchamber, which enables a measurement in nanoliter volume. We measured the impedance which is reciprocal of conductivity using a lock-in amplifier and a precise current source at frequency of 130 Hz. Initially high impedance of mutant sample tended to drop within 2 hours and finally approached the constant value which signified that the cell death mechanism was complete. However, the wildtype sample demonstrated approximately constant impedance (conductivity) during the experiment.

Physical Description

v, 58 p. : ill.

Language

Identifier

Unique identifying numbers for this thesis in the Digital Library or other systems.

Collections

This thesis is part of the following collection of related materials.

UNT Theses and Dissertations

Theses and dissertations represent a wealth of scholarly and artistic content created by masters and doctoral students in the degree-seeking process. Some ETDs in this collection are restricted to use by the UNT community.

What responsibilities do I have when using this thesis?

When

Dates and time periods associated with this thesis.

Creation Date

  • August 2010

Added to The UNT Digital Library

  • March 30, 2011, 9:15 p.m.

Description Last Updated

  • May 5, 2011, 11:20 a.m.

Usage Statistics

When was this thesis last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 568

Interact With This Thesis

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Abtahi, Seyed Ali. Ultrafast Laser Sampling of a Plant Tissue and ion Conductivity Measurement for Investigation of Light Stress Generation Mechanisms, thesis, August 2010; Denton, Texas. (https://digital.library.unt.edu/ark:/67531/metadc31522/: accessed April 23, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; .

Back to Top of Screen