Establishing the Leakage Rates of Mobile Air Conditioners Page: Front Cover
ii, 55 p. : ill.View a full description of this text.
Extracted Text
The following text was automatically extracted from the image on this page using optical character recognition software:
Final Report
on
Establishing the Leakage Rates of Mobile Air
Conditioners
(B4-3040/2002/3371 36/MAR/C1)
Prepared for the
European Commission (DG Environment)
by
Winfried Schwarz (Oko-Recherche) & Jochen Harnisch (Ecofys)
Contact:
Oko-Recherche GmbH
Winfried Schwarz
Kaiserstr. 61
60329 Frankfurt
Germany
phone: +49 69 25 23 05
ws@oekorecherche.de
17. April 2003
Upcoming Pages
Here’s what’s next.
Search Inside
This text can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Text.
Schwarz, Winfried & Harnisch, Jochen. Establishing the Leakage Rates of Mobile Air Conditioners, text, April 17, 2003; [Brussels, Belgium]. (https://digital.library.unt.edu/ark:/67531/metadc29372/m1/1/: accessed April 25, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; .