ACTIVITIES
3. MODIFICATIONS
Major modifications made to the 17 Effect Plant during the reporting period for
process and materials testing follow. An updated process and instrumenta-
tion diagram is attached in Part 2 of the appendix.
A. Flash Tanks
In order to evaluate modular performance properly, a knowledge of
condensate level is necessary. Level sight glasses were installed
on flash tanks 14, 15, and 16 in July, 1968. The module came
equipped with glasses on flash tanks 13 and 11 only.
During runs 14 and 15, the carbon steel shells of external flash
tanks 10, 11 and 12 all perforated at the external support ring;
they were replaced. Failure was attributed to external, general
surface corrosion. Data on the new tanks are:Installation
DateMaterial
Insulation
11-68
5-69
4-69Glass Reinforced
Polyester
Epoxy Coated
Carbon Steel
Epoxy Coated
Carbon SteelNone
1-1/2" Calsite
1-1/2" CalsiteB. Brine Piping and Valves
Several large test spools were installed in Brine Service. A summary
of these installations follow:Material
Installation
DateRemarks
P-11 Discharge
P-12 Discharge
P-18 Discharge316 L S.S.
Bondstrand 2000
Fibercast OG-20257-68
7-68
8-68Still in Service
Many Failures
Still in ServiceTwo Teflon expansion bellows were installed at pump suctions to
relieve stress on the pumps. Also, one Dresser coupling was tested.
These items are summarized below:Device
Teflon Bellows
Teflon Bellows
Dresser CouplingInstallation
Date11-68
12-68
12-68Service
Temp.
Ambient
2660F
2400FRemarks
Original Installation
Replaced Monel Bellows
Replaced Monel Bellows-71-
Flash
Tank No.10
11
12Location
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Campbell, Keith S. & Williams, Donald L. Annual Report (FY 1969): Freeport Test Facility and Vertical-Tube-Evaporator Test-Bed Plant, Freeport, Texas, report, 1969; Washington D.C.. (https://digital.library.unt.edu/ark:/67531/metadc11743/m1/78/: accessed April 24, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.