Frequency-Response Analysis of Steam Voids to Sinusoidal Power Modulation in a Thin-Walled Boiling Water Coolant Channel

Description:

Report regarding a study with the primary objective of acquiring "experimental data on power-to-void transfer functions for a single rectangular flow channel at elevated pressures" (p. 9).

Creator(s):
Creation Date: May 1965
Partner(s):
UNT Libraries Government Documents Department
Collection(s):
Technical Report Archive and Image Library
Usage:
Total Uses: 106
Past 30 days: 11
Yesterday: 0
Creator (Author):
St. Pierre, Carl C.

Reactor Engineering Division, ANL and Associated Midwest Universities

Creator (Author):
Argonne National Laboratory

9700 South Cass Avenue, Argonne, Illinois 60440

Publisher Info:
Publisher Name: Argonne National Laboratory
Place of Publication: Argonne, Illinois
Date(s):
  • Creation: May 1965
Description:

Report regarding a study with the primary objective of acquiring "experimental data on power-to-void transfer functions for a single rectangular flow channel at elevated pressures" (p. 9).

Note:

"Operated by The University of Chicago under Contract W-31-109-eng-38 with the U. S. Atomic Energy Commission." "Based on a thesis Submitted to the Faculty of the Graduate School of Northwestern University in partial fulfillment of the requirements for the degree of Doctor of Philosophy."

Note:

"Engineering and Equipment< (TID-4500, 46th Ed.), AEC Research and Development Report."

Physical Description:

147 p. : ill. : graphs, ill., tables

Language(s):
Subject(s):
Contributor(s):
Series Title: Argonne National Laboratory Reports
Added Title: Argonne National Laboratory Report ANL-7041
Partner:
UNT Libraries Government Documents Department
Collection:
Technical Report Archive and Image Library
Identifier:
  • REP-NO: ANL-7041
  • OCLC: 652826569 |
  • ARK: ark:/67531/metadc11597
  • ARK: ark:/67531/metadc11597
Resource Type: Report
Format: Text