Dynamic Measurement of Intraoral Pressure and Sound Pressure With Laryngoscopic Characterization During Oboe Performance

Description:

Measurements of intraoral pressure (IOP) and sound pressure level (SPL) were taken of four oboists as they performed two sets of musical exercises: (1) crescendo-decrescendo from pp to ff and back to pp on the pitches D4, G4, C5 and A5, and (2) straight and vibrato performances of the same four pitches at mf. Video images of the vocal tract were also made using flexible fiberoptic nasoendoscopy (FFN). IOP and SPL data were captured in real time by the WinDaq®/Lite software package, with the dB meter located 8-9 inches in directly front of the oboe bell. The study yielded minimum and maximum values from 21.04 to 57.81 mm Hg and from 65.53 to 100.89 dB across all pitches examined. Discussion is included for the following topics: (1) the oboe’s sound envelope, or functional range of IOP and SPL values at different pitch levels, including the nonlinearity in the relationship between IOP and SPL on the oboe, (2) the static activation and kinetic maintenance thresholds for reed vibration, (3) the effect of vibrato on IOP/SPL, (4) the utilization of the vocal tract during execution of dynamic changes and vibrato, and (5) the impact of player experience on control of physical variables.

Creator(s): Adduci, Michael Douglas
Creation Date: December 2011
Partner(s):
UNT Libraries
Collection(s):
UNT Theses and Dissertations
Usage:
Total Uses: 285
Past 30 days: 47
Yesterday: 0
Creator (Author):
Publisher Info:
Publisher Name: University of North Texas
Publisher Info: www.unt.edu
Place of Publication: Denton, Texas
Date(s):
  • Creation: December 2011
Description:

Measurements of intraoral pressure (IOP) and sound pressure level (SPL) were taken of four oboists as they performed two sets of musical exercises: (1) crescendo-decrescendo from pp to ff and back to pp on the pitches D4, G4, C5 and A5, and (2) straight and vibrato performances of the same four pitches at mf. Video images of the vocal tract were also made using flexible fiberoptic nasoendoscopy (FFN). IOP and SPL data were captured in real time by the WinDaq®/Lite software package, with the dB meter located 8-9 inches in directly front of the oboe bell. The study yielded minimum and maximum values from 21.04 to 57.81 mm Hg and from 65.53 to 100.89 dB across all pitches examined. Discussion is included for the following topics: (1) the oboe’s sound envelope, or functional range of IOP and SPL values at different pitch levels, including the nonlinearity in the relationship between IOP and SPL on the oboe, (2) the static activation and kinetic maintenance thresholds for reed vibration, (3) the effect of vibrato on IOP/SPL, (4) the utilization of the vocal tract during execution of dynamic changes and vibrato, and (5) the impact of player experience on control of physical variables.

Degree:
Department: College of Music
Discipline: Performance
Level: Doctoral
PublicationType: Doctoral Dissertation
Language(s):
Subject(s):
Keyword(s): Oboe | intraoral pressure | laryngoscopy | FFN | vibrato | dynamics
Contributor(s):
Partner:
UNT Libraries
Collection:
UNT Theses and Dissertations
Identifier:
  • ARK: ark:/67531/metadc103281
Resource Type: Thesis or Dissertation
Format: Text
Rights:
Access: Public
Holder: Adduci, Michael Douglas
License: Copyright
Statement: Copyright is held by the author, unless otherwise noted. All rights Reserved.